Literature DB >> 18027012

The influence of external ultrasound on the histologic architecture of the organic capsule around smooth silicone implants: experimental study in rats.

F H Mendes1, F Viterbo, L DeLucca.   

Abstract

BACKGROUND: Capsular contracture is the main complication related to breast silicone implants, and its prevention remains a medical challenge. The authors present experimental research examining the effect of external ultrasound on the formation and contracture of peri-implant capsules.
METHODS: In this study, 42 male Wistar rats had a 2-mm smooth surface implant placed in a dorsal submuscular pocket. They then were separated into "ultrasound" and "control" groups that received repeated external applications either with or without the ultrasound power on. Ultrasound applications were given three times a week for a period of 90 days. After that, both groups were housed under the same conditions with no application scheduled. Five animals of each group, killed at 30, 60, 90, and 180 days, had their implants removed along with the capsule, which received a special histologic preparation via annular sectioning that provided wide circumferential observation of the capsular tissue. Sections were stained with hematoxylin/eosin stain, Masson's trichrome stain, and Pricrosirius Red stain for regular microscopic evaluation under normal and polarized light.
RESULTS: Histologic data showed that capsules from the ultrasound and control groups had statistically significant differences. Ultrasound application developed a capsular architecture similar to that shown within textured silicone implants, and its effect had an early definition with subsequent stabilization.
CONCLUSION: The authors conclude that early and repeated external ultrasound application enhances the thickness, cellular count, and vascularity of smooth silicone capsular tissue, whereas it diminishes the pattern of parallel orientation of collagen fibers.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18027012     DOI: 10.1007/s00266-007-9063-0

Source DB:  PubMed          Journal:  Aesthetic Plast Surg        ISSN: 0364-216X            Impact factor:   2.326


  2 in total

1.  Is the shear wave sonographic elastography correlated with pain after breast augmentation with silicone implants an indication of inflammatory activity? A preliminary report.

Authors:  Paweł Rzymski; Mikołaj Kubasik; Michał Gaca; Tomasz Opala
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2011-12-20       Impact factor: 1.195

2.  Evaluation of the biocompatibility of silicone gel implants - histomorphometric study.

Authors:  Diurianne Caroline Campos França; Alvimar Lima de Castro; Ana Maria Pires Soubhia; Sandra Maria Herondina Coelho Ávila de Aguiar; Marcelo Coelho Goiato
Journal:  Acta Inform Med       Date:  2013
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.