Literature DB >> 18026863

Picogram determination of estrogens in water using large volume injection gas chromatography-mass spectrometry.

Ruikang Hu1, Lifeng Zhang, Zhaoguang Yang.   

Abstract

In this study, a simple and efficient large volume injection gas chromatography-mass spectrometry (GC-MS) method, via a programmable-temperature vaporizer (PTV) inlet, has been developed and applied in the determination of estrogens in environmental water samples without a prior derivatization process. Three commonly used estrogens estrone, 17 beta-estradiol and 17 alpha-ethynylestradiol were selected as target compounds for this study. It has been demonstrated that the type of gas chromatograph liner and the initial inlet temperature can greatly affect the response intensity of estrogens. Three different types of PTV liners have been studied; the multibaffle liner generated the strongest response intensities towards the estrogen analytes. The results showed that the response intensities of estrogens reduced sharply while the initial inlet temperature increased. Various instrument conditions and sample preparation methods were studied in detail. The optimized method has been validated with good linearity, precision and accuracy. The method detection limit of each estrogen was found to be 0.041 ng/L for estrone, 0.046 ng/L for 17 beta-estradiol and 0.031 ng/L for 17 alpha-ethynylestradiol. To the best of our knowledge, these results represent the best sensitivities achieved for estrogens analyzed in water samples via traditional GC-MS method without a derivatization process. This method has been successfully applied in the analyses of different water samples.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18026863     DOI: 10.1007/s00216-007-1683-3

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  2 in total

Review 1.  Reproductive drugs and environmental contamination: quantum, impact assessment and control strategies.

Authors:  Harpreet Kaur; Madhu Bala; Gulshan Bansal
Journal:  Environ Sci Pollut Res Int       Date:  2018-07-23       Impact factor: 4.223

2.  Separation of dansylated 17β-estradiol, 17α-estradiol, and estrone on a single HPLC column for simultaneous quantitation by LC-MS/MS.

Authors:  Szabolcs Szarka; Vien Nguyen; Laszlo Prokai; Katalin Prokai-Tatrai
Journal:  Anal Bioanal Chem       Date:  2013-02-01       Impact factor: 4.142

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.