Literature DB >> 18026266

In vivo three-dimensional spectral domain endoscopic optical coherence tomography using a microelectromechanical system mirror.

Woonggyu Jung1, Daniel T McCormick, Yeh-Chan Ahn, Ali Sepehr, Matt Brenner, Brian Wong, Norman C Tien, Zhongping Chen.   

Abstract

A biopsy is a well-known medical test used to evaluate tissue abnormality. Biopsy specimens are invasively taken from part of a lesion and visualized by microscope after chemical treatment. However, diagnosis by means of biopsy is not only variable due to depth and location of specimen but may also damage the specimen. In addition, only a limited number of specimens can be obtained, thus, the entire tissue morphology cannot be observed. We introduce a three-dimensional (3-D) endoscopic optical biopsy via optical coherence tomography employing a dual-axis microelectromechanical system scanning mirror. Since this technique provides high-resolution, noninvasive, direct, and multiple visualization of tissue, it could function as a clinical biopsy with advanced performance. The device was integrated with a conventional endoscope and utilized to generate in vivo 3-D clinical images in humans and animals.

Entities:  

Mesh:

Year:  2007        PMID: 18026266     DOI: 10.1364/ol.32.003239

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  15 in total

1.  Miniaturized probe based on a microelectromechanical system mirror for multiphoton microscopy.

Authors:  Woonggyu Jung; Suo Tang; Daniel T McCormic; Tiquiang Xie; Yeh-Chan Ahn; Jianping Su; Ivan V Tomov; Tatiana B Krasieva; Bruce J Tromberg; Zhongping Chen
Journal:  Opt Lett       Date:  2008-06-15       Impact factor: 3.776

2.  Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

Authors:  Yizheng Zhu; Neil G Terry; John T Woosley; Nicholas J Shaheen; Adam Wax
Journal:  J Biomed Opt       Date:  2011 Jan-Feb       Impact factor: 3.170

3.  Design of a handheld optical coherence microscopy endoscope.

Authors:  Vrushali R Korde; Erica Liebmann; Jennifer K Barton
Journal:  J Biomed Opt       Date:  2011-06       Impact factor: 3.170

4.  Multimodal nonlinear endo-microscopy probe design for high resolution, label-free intraoperative imaging.

Authors:  Xu Chen; Xiaoyun Xu; Daniel T McCormick; Kelvin Wong; Stephen T C Wong
Journal:  Biomed Opt Express       Date:  2015-06-03       Impact factor: 3.732

Review 5.  Three dimensional optical coherence tomography imaging: advantages and advances.

Authors:  Michelle L Gabriele; Gadi Wollstein; Hiroshi Ishikawa; Juan Xu; Jongsick Kim; Larry Kagemann; Lindsey S Folio; Joel S Schuman
Journal:  Prog Retin Eye Res       Date:  2010-06-11       Impact factor: 21.198

6.  Handheld optical coherence tomography scanner for primary care diagnostics.

Authors:  Woonggyu Jung; Jeehyun Kim; Mansik Jeon; Eric J Chaney; Charles N Stewart; Stephen A Boppart
Journal:  IEEE Trans Biomed Eng       Date:  2010-12-03       Impact factor: 4.538

Review 7.  A biological global positioning system: considerations for tracking stem cell behaviors in the whole body.

Authors:  Shengwen Calvin Li; Lisa May Ling Tachiki; Jane Luo; Brent A Dethlefs; Zhongping Chen; William G Loudon
Journal:  Stem Cell Rev Rep       Date:  2010-06       Impact factor: 5.739

8.  Non-invasive optical interferometry for the assessment of biofilm growth in the middle ear.

Authors:  Cac T Nguyen; Haohua Tu; Eric J Chaney; Charles N Stewart; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2010-10-07       Impact factor: 3.732

9.  Semi-resonant operation of a fiber-cantilever piezotube scanner for stable optical coherence tomography endoscope imaging.

Authors:  Sucbei Moon; Sang-Won Lee; Marc Rubinstein; Brian J F Wong; Zhongping Chen
Journal:  Opt Express       Date:  2010-09-27       Impact factor: 3.894

10.  Handheld miniature probe integrating diffuse optical tomography with photoacoustic imaging through a MEMS scanning mirror.

Authors:  Hao Yang; Lei Xi; Sean Samuelson; Huikai Xie; Lily Yang; Huabei Jiang
Journal:  Biomed Opt Express       Date:  2013-02-15       Impact factor: 3.732

View more