Literature DB >> 18023278

Calcium addition to EDTA plasma eliminates falsely positive results in the RSR GADAb ELISA.

Emma Nilson1, Birgitte Ekholm, Bernard Rees Smith, Carina Törn, Magnus Hillman.   

Abstract

BACKGROUND: The RSR ELISAs for GADAb and IA-2Ab are now widely used but due to a considerable number of falsely positive GADAb results obtained with EDTA plasma, it is recommended that only serum samples are run in these two assays. However, as EDTA plasma is often the preferred sample type in Europe we have assessed the possibility that adding Ca(2+) to plasma would reduce the number of falsely positive results.
METHODS: Antibody positive as well as antibody negative diabetic subjects were included in the study (n=80). Serum and EDTA plasma were collected from the same subjects at the same occasion. Samples were divided into three groups; sera, EDTA plasma and EDTA plasma+Ca(2+). ELISA kits were supplied by RSR Ltd and performed according to the manufacturers instructions.
RESULTS: GADAb analyses with plasma showed a markedly increased prevalence of GADAb positive subjects (81%) compared to sera (36%), indicating falsely positive results with plasma. Addition of Ca(2+) reduced the number of GADAb positive results to the same number obtained with serum. IA-2Ab positivity was not different between sera and plasma.
CONCLUSION: EDTA plasma can be used in the RSR GADAb and IA-2Ab ELISAs if Ca(2+) is added prior to assay.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18023278     DOI: 10.1016/j.cca.2007.10.021

Source DB:  PubMed          Journal:  Clin Chim Acta        ISSN: 0009-8981            Impact factor:   3.786


  4 in total

1.  Comparison of measurements of autoantibodies to glutamic acid decarboxylase and islet antigen-2 in whole blood eluates from dried blood spots using the RSR-enzyme linked immunosorbent assay kits and in-house radioimmunoassays.

Authors:  Anders Persson; Charlotte Becker; Ida Hansson; Anita Nilsson; Carina Törn
Journal:  Exp Diabetes Res       Date:  2010-06-03

2.  Measuring carbonic anhydrase IX as a hypoxia biomarker: differences in concentrations in serum and plasma using a commercial enzyme-linked immunosorbent assay due to influences of metal ions.

Authors:  Tobias C Wind; Michael P Messenger; Douglas Thompson; Peter J Selby; Rosamonde E Banks
Journal:  Ann Clin Biochem       Date:  2011-03-02       Impact factor: 2.057

3.  Demographic associations for autoantibodies in disease-free individuals of a European population.

Authors:  Kadri Haller-Kikkatalo; Kristi Alnek; Andres Metspalu; Evelin Mihailov; Kaja Metsküla; Kalle Kisand; Heti Pisarev; Andres Salumets; Raivo Uibo
Journal:  Sci Rep       Date:  2017-03-28       Impact factor: 4.379

4.  Blood B Cell Depletion Reflects Immunosuppression Induced by Live-Attenuated Infectious Bursal Disease Vaccines.

Authors:  Céline Courtillon; Chantal Allée; Michel Amelot; Alassane Keita; Stéphanie Bougeard; Sonja Härtle; Jean-Claude Rouby; Nicolas Eterradossi; Sebastien Mathieu Soubies
Journal:  Front Vet Sci       Date:  2022-04-25
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.