Literature DB >> 18018605

Initial clinical experience with a new end graft holder for anastomosis in coronary surgery.

Yoshiei Shimamura1, Yoshihiko Mochizuki, Yasuyuki Yamada, Kunihiro Eda, Ikuko Shibasaki, Yuho Inoue, Fumie Saito, Shinichiro Miyoshi.   

Abstract

OBJECTIVE: We assessed the feasibility and effectiveness of a novel end graft holder for coronary artery bypass grafting (CABG) and evaluated anastomotic patency and early clinical results.
METHODS: The end graft holder was applied to 45 consecutive patients. Operative characteristics were off-pump CABG in 22.2%, emergency in 28.9%, and concomitant cardiac surgery in 13.3%.
RESULTS: The device was used safely without graft injury or inadequate gripping on grafts. Postoperative angiography showed that the patency rate of distal anastomosis was 96.7% (arterial, 100%; venous, 94%). All proximal aortic and composite graft anastomoses were patent without stenosis. The rate of 30-day major adverse cardiac and cerebrovascular events was 13.3% (operative deaths, 3; repeated CABG, 1; percutaneous coronary arterial intervention, 1; and cerebral infarction, 1). None of the elective patients died during hospitalization.
CONCLUSION: Our initial clinical experience demonstrated that the new end graft holder was safe, reliable, and effective during CABG. The excellent fixation and visualization of the graft with the device might be particularly beneficial for off-pump CABG or for teaching trainees.

Entities:  

Mesh:

Year:  2007        PMID: 18018605     DOI: 10.1007/s11748-007-0155-1

Source DB:  PubMed          Journal:  Gen Thorac Cardiovasc Surg        ISSN: 1863-6705


  10 in total

1.  New graft holder for coronary artery bypass using arterial conduits.

Authors:  M Endo; H Nishida; H Koyanagi
Journal:  Ann Thorac Cardiovasc Surg       Date:  1999-08       Impact factor: 1.520

2.  Survey of resident training in beating heart operations.

Authors:  M Ricci; H L Karamanoukian; G D'Ancona; J DeLaRosa; R L Karamanoukian; S Choi; J Bergsland; T A Salerno
Journal:  Ann Thorac Surg       Date:  2000-08       Impact factor: 4.330

Review 3.  Clinical experience with devices for facilitated anastomoses in coronary artery bypass surgery.

Authors:  Thierry P Carrel; Friedrich S Eckstein; Lars Englberger; Pascal A Berdat; Jürg Schmidli
Journal:  Ann Thorac Surg       Date:  2004-03       Impact factor: 4.330

4.  Early clinical results with a magnetic connector for distal coronary artery anastomoses.

Authors:  Calin Vicol; Sandra Eifert; Martin Oberhoffer; Peter Boekstegers; Andreas Knez; Frank Christ; Bruno Reichart
Journal:  Ann Thorac Surg       Date:  2005-05       Impact factor: 4.330

5.  The Society of Thoracic Surgeons/American Association for Thoracic Surgery off-pump training program.

Authors:  Richard P Anderson; Meghan Carey; Evelyn Baram-Clothier; Michael J Mack; Bruce W Lytle
Journal:  Ann Thorac Surg       Date:  2006-02       Impact factor: 4.330

6.  Thoracic and cardiovascular surgery in Japan during 2004.

Authors:  Teruhisa Kazui; Hiroaki Osada; Hiromasa Fujita
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-08

7.  Vein holder for coronary bypass surgery.

Authors:  H Suma; A Takeuchi
Journal:  Ann Thorac Surg       Date:  1987-01       Impact factor: 4.330

8.  Vascular anastomosis with Mobin-Uddin vein/graft holder.

Authors:  K Mobin-Uddin; R Pleasant
Journal:  Ann Thorac Surg       Date:  1986-11       Impact factor: 4.330

9.  A new mechanical connector for distal coronary artery anastomoses in coronary artery bypass grafting: a randomized, controlled study.

Authors:  L Wiklund; L F Bonilla; E Berglin
Journal:  J Thorac Cardiovasc Surg       Date:  2005-01       Impact factor: 5.209

10.  Clinical and angiographic results after mechanical connection for distal anastomosis in coronary surgery.

Authors:  Thierry Carrel; Lars Englberger; Dorothee Keller; Stephan Windecker; Bernhard Meier; Friedrich Eckstein
Journal:  J Thorac Cardiovasc Surg       Date:  2004-06       Impact factor: 5.209

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.