Literature DB >> 18018401

Insulin binding to the cardiopulmonary bypass biomaterials.

Kristyn Urban1, Daniel Redford, Douglas F Larson.   

Abstract

Hyperglycemia associated with cardiopulmonary bypass (CPB) is an independent predictor of morbidity and mortality. One suggested cause of hyperglycemia during CPB is a decline of serum insulin concentrations. Since plasma C-proteins are not reduced during CPB -suggesting that pancreatic insulin secretion is not affected - the reduction of insulin concentrations is hypothesized to be due to the binding of the insulin protein to the CPB biomaterials. The hypothesis of this study is that insulin binds to the CPB polyvinyl chloride (PVC) tubing and that selected bio-coatings inhibit this process. Human insulin was diluted to a physiologic concentration of 30 microU/mL in saline and exposed to four types of sterile PVC tubing, namely: uncoated, Terumo X-coated, Medtronic Carmeda, and Cobe SMARx T for 30 minutes at 37 degrees C. Insulin concentrations were determined with ELISA. The recovered insulin concentrations were found to be 9.3 +/- 0.6 microU/mL in the uncoated (control), 17.7 +/- 1.9 microU/mL in the X-coating, 17.9 +/- 1.1 microU/mL in the Carmeda, and 14.28 +/- 0.17 microU/mL in the SMARxT coated tubing. These data support the hypothesis that the insulin binding to the PVC tubing can be reduced by 48% and up to 35% with X-coating and Carmeda, and SMARxT coating, respectively. Therefore, the use of coated CPB systems is justified to reduce CPB-associated hyperglycemia.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 18018401     DOI: 10.1177/0267659107081632

Source DB:  PubMed          Journal:  Perfusion        ISSN: 0267-6591            Impact factor:   1.972


  3 in total

1.  Extracorporeal tubing in the roller pump raceway: physical changes and particulate generation.

Authors:  Allison J Bednarski Spiwak; Alexander Horbal; Robert Leatherbury; Derek J Hansford
Journal:  J Extra Corpor Technol       Date:  2008-09

Review 2.  Development and hemocompatibility testing of nitric oxide releasing polymers using a rabbit model of thrombogenicity.

Authors:  Terry C Major; Hitesh Handa; Gail M Annich; Robert H Bartlett
Journal:  J Biomater Appl       Date:  2014-06-16       Impact factor: 2.646

3.  Factors associated with hyperglycemia and low insulin levels in children undergoing cardiac surgery with cardiopulmonary bypass who received a single high dose of methylprednisolone.

Authors:  Ronaldo Arkader; Luiz Marcelo Malbouisson; Gilda Maria Barbaro Del Negro; Lidia Yamamoto; Thelma Suely Okay
Journal:  Clinics (Sao Paulo)       Date:  2013-01       Impact factor: 2.365

  3 in total