Literature DB >> 18008113

The skin-traction method increases the cross-sectional area of the internal jugular vein by increasing its anteroposterior diameter.

Masato Morita1, Hiroshi Sasano, Takafumi Azami, Nobuko Sasano, Hirotada Katsuya.   

Abstract

PURPOSE: We developed a novel "skin-traction method" in which the puncture point of the skin over the internal jugular vein (IJV) is stretched upward with several pieces of surgical tape in the cephalad and caudad directions to facilitate cannulation of the IJV. We investigated whether this method increases the cross-sectional area of the IJV.
METHODS: In 11 healthy volunteers, the cross-sectional area, anteroposterior diameter, and transverse diameter of the right IJV (RIJV) were recorded by ultrasound echo at head tilts of +10 degrees , +5 degrees , 0 degrees , -5 degrees , and -10 degrees with and without the skin-traction method.
RESULTS: The skin-traction method significantly increased the cross-sectional areas of the RIJV at head tilts of +10 degrees , +5 degrees , and 0 degrees . In the flat position, the skin-traction method increased the cross-sectional area of the RIJV from 1.21 +/- 0.44 cm(2) to 1.75 +/- 0.60 cm(2) (44.6% increase), which is almost the same as that in the Trendelenburg position without this method (1.60 +/- 0.54 cm(2) at -5 degrees and 1.83 +/- 0.56 cm(2) at -10 degrees ). The anteroposterior diameter of the RIJV was significantly increased in all positions with this method, although the transverse diameter was not.
CONCLUSION: This method significantly increased the cross-sectional area of the RIJV by increasing the anteroposterior diameter of the RIJV. Even in the flat position, this method was almost as efficacious as the Trendelenburg position. This method thus appears to facilitate IJV cannulation.

Mesh:

Year:  2007        PMID: 18008113     DOI: 10.1007/s00540-007-0562-6

Source DB:  PubMed          Journal:  J Anesth        ISSN: 0913-8668            Impact factor:   2.078


  8 in total

1.  Trendelenburg position, head elevation and a midline position optimize right internal jugular vein diameter.

Authors:  Gareth Parry
Journal:  Can J Anaesth       Date:  2004-04       Impact factor: 5.063

2.  Effects of clinical maneuvers on sonographically determined internal jugular vein size during venous cannulation.

Authors:  D L Mallory; T Shawker; R G Evans; W T McGee; M Brenner; M Parker; G Morrison; P Mohler; C Veremakis; J E Parrillo
Journal:  Crit Care Med       Date:  1990-11       Impact factor: 7.598

3.  Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture.

Authors:  C A Sulek; N Gravenstein; R H Blackshear; L Weiss
Journal:  Anesth Analg       Date:  1996-01       Impact factor: 5.108

4.  US-guided puncture of the internal jugular vein: complications and anatomic considerations.

Authors:  A C Gordon; J C Saliken; D Johns; R Owen; R R Gray
Journal:  J Vasc Interv Radiol       Date:  1998 Mar-Apr       Impact factor: 3.464

5.  Right internal jugular vein venography in infants and children.

Authors:  S Nakayama; M Yamashita; Y Osaka; T Isobe; H Izumi
Journal:  Anesth Analg       Date:  2001-08       Impact factor: 5.108

6.  The effect of position and different manoeuvres on internal jugular vein diameter size.

Authors:  P J Armstrong; R Sutherland; D H Scott
Journal:  Acta Anaesthesiol Scand       Date:  1994-04       Impact factor: 2.105

7.  Internal jugular vein catheterization in infants undergoing cardiovascular surgery: an analysis of the factors influencing successful catheterization.

Authors:  Y Hayashi; O Uchida; O Takaki; Y Ohnishi; T Nakajima; H Kataoka; M Kuro
Journal:  Anesth Analg       Date:  1992-05       Impact factor: 5.108

8.  Ultrasound-guided central venous cannulation in infants and children.

Authors:  P Asheim; U Mostad; P Aadahl
Journal:  Acta Anaesthesiol Scand       Date:  2002-04       Impact factor: 2.105

  8 in total
  1 in total

1.  Skin-traction method prevents the collapse of the internal jugular vein caused by an ultrasound probe in real-time ultrasound-assisted guidance.

Authors:  Hiroshi Sasano; Masato Morita; Takafumi Azami; Shoji Ito; Nobuko Sasano; Rina Kato; Hiroyuki Hirate; Hiroaki Ito; Akinori Takeuchi; Kazuya Sobue
Journal:  J Anesth       Date:  2009-02-22       Impact factor: 2.078

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.