Literature DB >> 18008075

Validation of a raw data-based synchronization signal (kymogram) for phase-correlated cardiac image reconstruction.

Dirk Ertel1, Tobias Pflederer, Stephan Achenbach, Marc Kachelriess, Peter Steffen, Willi A Kalender.   

Abstract

Phase-correlated reconstruction is commonly used in computed tomography (CT)-based cardiac imaging. Alternatively to the commonly used ECG, the raw data-based kymogram function can be used as a synchronization signal. We used raw data of 100 consecutive patient exams to compare the performance of kymogram function to the ECG signal. For objective validation the correlation of the ECG and the kymogram was assessed. Additionally, we performed a double-blinded comparison of ECG-based and kymogram-based phase-correlated images. The two synchronization signals showed good correlation indicated by a mean difference in the detected heart rate of negligible 0.2 bpm. The mean image quality score was 2.0 points for kymogram-correlated images and 2.3 points for ECG-correlated images, respectively (3: best; 0: worst). The kymogram and the ECG provided images adequate for diagnosis for 93 and 97 patients, respectively. For 50% of the datasets the kymogram provided an equivalent or even higher image quality compared with the ECG signal. We conclude that an acceptable image quality can be assured in most cases by the kymogram. Improvements of image quality by the kymogram function were observed in a noticeable number of cases. The kymogram can serve as a backup solution when an ECG is not available or lacking in quality.

Entities:  

Mesh:

Year:  2007        PMID: 18008075     DOI: 10.1007/s00330-007-0752-5

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  12 in total

1.  Advanced single-slice rebinning in cone-beam spiral CT.

Authors:  M Kachelriess; S Schaller; W A Kalender
Journal:  Med Phys       Date:  2000-04       Impact factor: 4.071

2.  High temporal resolution for multislice helical computed tomography.

Authors:  K Taguchi; H Anno
Journal:  Med Phys       Date:  2000-05       Impact factor: 4.071

3.  A retrospectively ECG-gated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artifacts for cardio-thoracic imaging with extended volume coverage.

Authors:  T Flohr; M Prokop; C Becker; U J Schoepf; A F Kopp; R D White; S Schaller; B Ohnesorge
Journal:  Eur Radiol       Date:  2002-04-25       Impact factor: 5.315

4.  ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart.

Authors:  M Kachelriess; S Ulzheimer; W A Kalender
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

5.  Internal densitometric gating for digital subtraction angiography.

Authors:  J A Seibert; M T Lantz; J Brock
Journal:  Invest Radiol       Date:  1989-05       Impact factor: 6.016

6.  Noninvasive coronary angiography with 16-detector row CT: effect of heart rate.

Authors:  Martin H K Hoffmann; Heshui Shi; Robert Manzke; Florian T Schmid; Leon De Vries; Michael Grass; Hans-Jürgen Brambs; Andrik J Aschoff
Journal:  Radiology       Date:  2004-11-18       Impact factor: 11.105

7.  An application of hierarchical kappa-type statistics in the assessment of majority agreement among multiple observers.

Authors:  J R Landis; G G Koch
Journal:  Biometrics       Date:  1977-06       Impact factor: 2.571

8.  Automatic phase determination for retrospectively gated cardiac CT.

Authors:  R Manzke; Th Köhler; T Nielsen; D Hawkes; M Grass
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

9.  Kymogram detection and kymogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Authors:  Marc Kachelriess; Dirk-Alexander Sennst; Wolfgang Maxlmoser; Willi A Kalender
Journal:  Med Phys       Date:  2002-07       Impact factor: 4.071

10.  Electrocardiogram-correlated image reconstruction from subsecond spiral computed tomography scans of the heart.

Authors:  M Kachelriess; W A Kalender
Journal:  Med Phys       Date:  1998-12       Impact factor: 4.071

View more
  3 in total

1.  Cardiac phase-correlated image reconstruction and advanced image processing in pulmonary CT imaging.

Authors:  Robert M Lapp; Marc Kachelriess; Dirk Ertel; Yiannis Kyriakou; Willi A Kalender
Journal:  Eur Radiol       Date:  2008-12-11       Impact factor: 5.315

2.  Automatic selection of optimal systolic and diastolic reconstruction windows for dual-source CT coronary angiography.

Authors:  H Seifarth; M Puesken; S Wienbeck; D Maintz; R Fischbach; W Heindel; K-U Juergens
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

3.  4D reconstruction of the beating embryonic heart from two orthogonal sets of parallel optical coherence tomography slice-sequences.

Authors:  Sandeep Bhat; Irina V Larina; Kirill V Larin; Mary E Dickinson; Michael Liebling
Journal:  IEEE Trans Med Imaging       Date:  2012-12-04       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.