Literature DB >> 18007724

Real-time phase-resolved functional optical coherence tomography by use of optical Hilbert transformation.

Yonghua Zhao, Zhongping Chen, Zhihua Ding, Hongwu Ren, J Stuart Nelson.   

Abstract

We have developed a novel real-time phase-resolved functional optical coherence tomography system that uses optical Hilbert transformation. When we use a resonant scanner in the reference arm of the interferometer, with an axial scanning speed of 4 kHz, the frame rate of both structural and Doppler blood-flow imaging with a size of 100 by 100 pixels is 10 Hz. The system has high sensitivity and a larger dynamic range for measuring the Doppler frequency shift that is due to moving red blood cells. Real-time images of in vivo blood flow in human skin obtained with this interferometer are presented.

Entities:  

Year:  2002        PMID: 18007724     DOI: 10.1364/ol.27.000098

Source DB:  PubMed          Journal:  Opt Lett        ISSN: 0146-9592            Impact factor:   3.776


  25 in total

1.  Depth profiling of photothermal compound concentrations using phase sensitive optical coherence tomography.

Authors:  Guangying Guan; Roberto Reif; Zhihong Huang; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2011-12       Impact factor: 3.170

2.  High-resolution wide-field imaging of retinal and choroidal blood perfusion with optical microangiography.

Authors:  Lin An; Hrebesh M Subhush; David J Wilson; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2010 Mar-Apr       Impact factor: 3.170

3.  Miniature fiber-optic force sensor for vitreoretinal microsurgery based on low-coherence Fabry-Pérot interferometry.

Authors:  Xuan Liu; Iulian I Iordachita; Xingchi He; Russell H Taylor; Jin U Kang
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-01-21

4.  Frequency tracking in optical Doppler tomography using an adaptive notch filter.

Authors:  Yueli Chen; Peter Willett; Quing Zhu
Journal:  J Biomed Opt       Date:  2007 Jan-Feb       Impact factor: 3.170

5.  Removing the depth-degeneracy in optical frequency domain imaging with frequency shifting.

Authors:  S Yun; G Tearney; J de Boer; B Bouma
Journal:  Opt Express       Date:  2004-10-04       Impact factor: 3.894

6.  Noninvasive imaging of retinal morphology and microvasculature in obese mice using optical coherence tomography and optical microangiography.

Authors:  Zhongwei Zhi; Jennifer R Chao; Tomasz Wietecha; Kelly L Hudkins; Charles E Alpers; Ruikang K Wang
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-02-20       Impact factor: 4.799

7.  Compensation of spectral and RF errors in swept-source OCT for high extinction complex demodulation.

Authors:  Meena Siddiqui; Serhat Tozburun; Ellen Ziyi Zhang; Benjamin J Vakoc
Journal:  Opt Express       Date:  2015-03-09       Impact factor: 3.894

8.  Label-free imaging of blood vessel morphology with capillary resolution using optical microangiography.

Authors:  Roberto Reif; Ruikang K Wang
Journal:  Quant Imaging Med Surg       Date:  2012-09

9.  Ultrahigh sensitive optical microangiography for in vivo imaging of microcirculations within human skin tissue beds.

Authors:  Lin An; Jia Qin; Ruikang K Wang
Journal:  Opt Express       Date:  2010-04-12       Impact factor: 3.894

10.  Effects of hypoxia on cochlear blood flow in mice evaluated using Doppler optical microangiography.

Authors:  Suzan Dziennis; Roberto Reif; Zhongwei Zhi; Alfred L Nuttall; Ruikang K Wang
Journal:  J Biomed Opt       Date:  2012-10       Impact factor: 3.170

View more