Literature DB >> 1800748

An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI).

F V Zananiri1, P C Jackson, P R Goddard, E R Davies, P N Wells.   

Abstract

A study was undertaken to examine the accuracy and precision of the measurement of flow by magnetic resonance imaging (MRI) with consideration to the equipment and patient related parameters that might be encountered in vivo. For this purpose, test objects were devised consisting of PVC tubing, in which the internal diameter simulated the size of the arteries in the body. The design of the test objects ensured that steady laminar flow was obtained in the sections being imaged. The calibration study suggests that, using MRI, flow can be measured in vitro with systematic error of better than 7.0 +/- 5.0% and random error of better than 7.5%. In general, flow measurements obtained from MRI were found to correlate well with the known flows. However, the results indicated that there are prerequisite conditions for the validity of the measurements, such as the selection of appropriate flow pulse sequences and velocity limits. Measurements taken at vertically 40 mm away from the isocentre of the magnetic field were significantly different (p less than 0.01) from that at the isocentre.

Entities:  

Mesh:

Year:  1991        PMID: 1800748     DOI: 10.3109/03091909109023704

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  11 in total

1.  In vivo evaluation of quantitative MR angiography in a canine carotid artery stenosis model.

Authors:  M Calderon-Arnulphi; S Amin-Hanjani; A Alaraj; M Zhao; X Du; S Ruland; X J Zhou; K R Thulborn; F T Charbel
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-11       Impact factor: 3.825

Review 2.  Cardiac magnetic resonance at high field: promises and problems.

Authors:  Ahmed M Gharib; Abdalla Elagha; Roderic I Pettigrew
Journal:  Curr Probl Diagn Radiol       Date:  2008 Mar-Apr

3.  Does acute caffeine ingestion alter brain metabolism in young adults?

Authors:  Feng Xu; Peiying Liu; James J Pekar; Hanzhang Lu
Journal:  Neuroimage       Date:  2015-01-30       Impact factor: 6.556

4.  Effect of hypoxia and hyperoxia on cerebral blood flow, blood oxygenation, and oxidative metabolism.

Authors:  Feng Xu; Peiying Liu; Juan M Pascual; Guanghua Xiao; Hanzhang Lu
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-27       Impact factor: 6.200

5.  MRI assessment of cerebral oxygen metabolism in cocaine-addicted individuals: hypoactivity and dose dependence.

Authors:  Peiying Liu; Hanzhang Lu; Francesca M Filbey; Carol A Tamminga; Yan Cao; Bryon Adinoff
Journal:  NMR Biomed       Date:  2014-04-22       Impact factor: 4.044

6.  Quantitative assessment of global cerebral metabolic rate of oxygen (CMRO2) in neonates using MRI.

Authors:  Peiying Liu; Hao Huang; Nancy Rollins; Lina F Chalak; Tina Jeon; Cathy Halovanic; Hanzhang Lu
Journal:  NMR Biomed       Date:  2014-01-07       Impact factor: 4.044

7.  Test-retest reproducibility of a rapid method to measure brain oxygen metabolism.

Authors:  Peiying Liu; Feng Xu; Hanzhang Lu
Journal:  Magn Reson Med       Date:  2012-04-19       Impact factor: 4.668

8.  Optimization of phase-contrast MRI for the quantification of whole-brain cerebral blood flow.

Authors:  Shin-Lei Peng; Pan Su; Fu-Nien Wang; Yan Cao; Rong Zhang; Hanzhang Lu; Peiying Liu
Journal:  J Magn Reson Imaging       Date:  2015-02-11       Impact factor: 4.813

9.  Acute effect of glucose on cerebral blood flow, blood oxygenation, and oxidative metabolism.

Authors:  Feng Xu; Peiying Liu; Juan M Pascual; Guanghua Xiao; Hao Huang; Hanzhang Lu
Journal:  Hum Brain Mapp       Date:  2014-10-16       Impact factor: 5.038

10.  Accounting for the role of hematocrit in between-subject variations of MRI-derived baseline cerebral hemodynamic parameters and functional BOLD responses.

Authors:  Feng Xu; Wenbo Li; Peiying Liu; Jun Hua; John J Strouse; James J Pekar; Hanzhang Lu; Peter C M van Zijl; Qin Qin
Journal:  Hum Brain Mapp       Date:  2017-10-11       Impact factor: 5.038

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.