Literature DB >> 18005786

One hundred consecutive laparoscopic Nissen's without the use of a bougie.

Victor Bochkarev1, Atif Iqbal, Yong Kwon Lee, Michelle Vitamvas, Dmitry Oleynikov.   

Abstract

BACKGROUND: The creation of a floppy and symmetric fundoplication over a bougie has been the standard of care in laparoscopic surgery. The use of a bougie carries a risk of esophageal perforation but lowers the risk of postoperative dysphagia. Intraoperative esophagogastroduodenoscopy (IEGD) can be used to assess the orientation and position of a properly constructed Nissen. The aim of this study was to determine if IEGD can replace the routine use of a bougie in the creation of a fundoplication.
METHODS: One hundred consecutive patients undergoing laparoscopic Nissen fundoplication from 2003 to 2005 were entered into a prospective database. IEGD was used in all patients instead of a bougie. Preoperative and postoperative data, including symptom scores, pH studies, manometry, and upper gastrointestinal studies, were analyzed.
RESULTS: All 100 patients completed the study for a mean follow-up period of 18 months. The mean surgical time was 102 minutes. The mean intraoperative endoscopy time was 14 minutes. There were a total of 24 (24%) alterations of the fundoplication performed according to endoscopic wrap creation. The most common alteration was removal of a fundoplication stitch in 15 patients with a tight appearance of wrap. There were no major complications. Two patients required esophageal dilatation for mild to moderate dysphagia.
CONCLUSIONS: IEGD is a valuable tool for laparoscopic Nissen fundoplication. IEGD helps to appreciate the true location of the gastroesophageal junction and allows for fundoplication adjustment based on additional visualization. The creation of a symmetric and floppy wrap during Nissen fundoplication can be facilitated greatly by intraoperative endoscopy and may lead to improved clinical outcomes without the risk of esophageal perforation.

Entities:  

Mesh:

Year:  2007        PMID: 18005786     DOI: 10.1016/j.amjsurg.2007.08.042

Source DB:  PubMed          Journal:  Am J Surg        ISSN: 0002-9610            Impact factor:   2.565


  1 in total

1.  Laparoscopic tailored Nissen fundoplication.

Authors:  Hitoshi Idani; Shinya Asami; Takashi Ishikawa; Shinichiro Kubo; Takayuki Iwamoto; Shinichiro Watanabe; Hitoshi Kin
Journal:  Surg Endosc       Date:  2010-02-23       Impact factor: 4.584

  1 in total