Literature DB >> 18004717

Fused-core particle technology as an alternative to sub-2-microm particles to achieve high separation efficiency with low backpressure.

Jennifer M Cunliffe1, Todd D Maloney.   

Abstract

Fused-Core particles have recently been introduced as an alternative to using sub-2-microm particles in chromatographic separations. Fused-Core particles are composed of a 1.7 microm solid core surrounded by a 0.5 microm porous silica layer (d(p) = 2.7 microm) to reduce mass transfer and increase peak efficiency. The performance of two commercially available Fused-Core particles (Advanced Materials Technology Halo C18 and Supelco Ascentis Express C18) was compared with sub-2-microm particles from Waters, Agilent, and Thermo Scientific. Although the peak efficiencies were only approximately 80% of those obtained by the Waters Acquity particles, the 50% lower backpressure allowed columns to be coupled in series to increase peak efficiency to 92,750 plates. The low backpressure and high efficiencies of the Fused-Core particles offer a viable alternative to using sub-2-microm particles and very-high-pressure LC instrumentation.

Entities:  

Mesh:

Year:  2007        PMID: 18004717     DOI: 10.1002/jssc.200700260

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  10 in total

Review 1.  Perspectives on recent advances in the speed of high-performance liquid chromatography.

Authors:  Peter W Carr; Dwight R Stoll; Xiaoli Wang
Journal:  Anal Chem       Date:  2011-02-22       Impact factor: 6.986

2.  Performance characteristics of new superficially porous particles.

Authors:  Joseph J Destefano; Stephanie A Schuster; Jason M Lawhorn; Joseph J Kirkland
Journal:  J Chromatogr A       Date:  2012-08-17       Impact factor: 4.759

3.  Fast high performance liquid chromatography separations for proteomic applications using Fused-Core® silica particles.

Authors:  Stephanie A Schuster; Barry E Boyes; Brian M Wagner; Joseph J Kirkland
Journal:  J Chromatogr A       Date:  2011-07-30       Impact factor: 4.759

4.  An improved approach to hydrophilic interaction chromatography of peptides: salt gradients in the presence of high isocratic acetonitrile concentrations.

Authors:  Colin T Mant; Ziqing Jiang; Barry E Boyes; Robert S Hodges
Journal:  J Chromatogr A       Date:  2013-01-01       Impact factor: 4.759

5.  Reversed-phase chromatography with large pore superficially porous particles for high throughput immunoglobulin G2 disulfide isoform separation.

Authors:  Bingchuan Wei; Bing Zhang; Barry Boyes; Yonghua Taylor Zhang
Journal:  J Chromatogr A       Date:  2017-10-18       Impact factor: 4.601

6.  Reversed-phase fused-core HPLC modeling of peptides.

Authors:  Matthias D'Hondt; Bert Gevaert; Sofie Stalmans; Sylvia Van Dorpe; Evelien Wynendaele; Kathelijne Peremans; Christian Burvenich; Bart De Spiegeleer
Journal:  J Pharm Anal       Date:  2012-11-30

7.  Fused-core particle technology in high-performance liquid chromatography: An overview.

Authors:  Joseph J Kirkland; Stephanie A Schuster; William L Johnson; Barry E Boyes
Journal:  J Pharm Anal       Date:  2013-02-27

Review 8.  Assessment of greenness for the determination of voriconazole in reported analytical methods.

Authors:  Hemanth Kumar Chanduluru; Abimanyu Sugumaran
Journal:  RSC Adv       Date:  2022-02-28       Impact factor: 3.361

9.  Quantification of Oxidized and Unsaturated Bile Alcohols in Sea Lamprey Tissues by Ultra-High Performance Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Ke Li; Anne M Scott; Yu-Wen Chung-Davidson; Ugo Bussy; Trinkal Patel; Zoe E Middleton; Weiming Li
Journal:  Molecules       Date:  2016-08-24       Impact factor: 4.411

10.  Mass spectrometry detection of basic drugs in fast chiral analyses with vancomycin stationary phases.

Authors:  Hongyue Guo; M Farooq Wahab; Alain Berthod; Daniel W Armstrong
Journal:  J Pharm Anal       Date:  2018-08-09
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.