Literature DB >> 18003322

A new method for Intra Ocular Pressure in vivo measurement: first clinical trials.

Patrick Dubois1, Jaouad Zemmouri, Jean Francois Rouland, Pierre Paul Elena, Renaud Lopes, Philippe Puech.   

Abstract

Glaucoma is an ocular disease clinically manifested by an abnormal rise of the Intra Ocular Pressure (IOP) that causes lesions of the optic nerve and can lead to blindness. Ophthalmologists currently use applanation tonometers whose utilization induces multiple constraints. We propose an investigative method being at one and the same time atraumatic and ambulatory. This original device, taking profit of a physical relation between frequency of mechanical vibration of the ocular globe and IOP, involves vibrometry by laser interferometry and spectral analysis of a mechanical impulse using a temporal micro hammer. The laser energy delivered to the eye by the device was confirmed to be safe and in full agreement with the authorized security norms. After preliminary in vitro experiments performed using enucleated animal eyes, we made a clinical study on 25 volunteers to evaluate the innocuity and the reliability of this device and to quantify the reproducibility of measurements. All patients declared that discomfort is comparable with that felt during similar tests. Reliability is good and the intra individual reproducibility reveals a high value (R > or = 0.93). These works will be carried on to check the correlation between the variation of measured values (resonance frequency of the eye-ball) and the variation of reference (IOP) values.

Entities:  

Mesh:

Year:  2007        PMID: 18003322     DOI: 10.1109/IEMBS.2007.4353656

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  3 in total

1.  Novel Applications of Laser Doppler Vibration Measurements to Medical Imaging.

Authors:  Habib Tabatabai; David E Oliver; John W Rohrbaugh; Christopher Papadopoulos
Journal:  Sens Imaging       Date:  2013-08-13

2.  Numerical model of optical coherence tomographic vibrography imaging to estimate corneal biomechanical properties.

Authors:  Sabine Kling; Imran B Akca; Ernest W Chang; Giuliano Scarcelli; Nandor Bekesi; Seok-Hyun Yun; Susana Marcos
Journal:  J R Soc Interface       Date:  2014-12-06       Impact factor: 4.118

3.  Eye orbit effects on eyeball resonant frequencies and acoustic tonometer measurements.

Authors:  Po-Jen Shih; Shao-Jie Wu; Ya-Hsing Sung; Yu-Ting Tung; Chia-Yu Chang; Shadie Hatamie; Zhi-Xuan Dai
Journal:  Sci Rep       Date:  2022-03-22       Impact factor: 4.379

  3 in total