Literature DB >> 18002774

Whole-body and thoracic bioimpedance measurement: hypertension and hyperhydration in hemodialysis patients.

L Nescolarde, P Bogónez, J Calpe, R Hernández, T Doñate, J Rosell.   

Abstract

Mono-frequency (50 kHz) and multi-frequency (3 kHz - 1 MHz) whole-body and thoracic segment bioimpedance measurement were doing before and after hemodialysis session in 20 patients. The patients were classified in hypertensive or non-hypertensive according to the mean blood pressure, BPmean. The relation between hyper-hydration in thorax segment through real part of impedance and mean blood pressure was analyzed. Also the bioelectrical impedance vector analysis method was used to analyze the displacement of Z/H vector in order to establish the relation with hyper-hydration (edema). Finally we made multi-frequency measurements with the objective to find a significative change in high and low frequency. We obtained a significant difference (P < 0.05) in impedance parameters before and after HD session. Some patients are located in hyper-hydration zone, below the inferior pole of the 75% tolerance ellipse, whereas others patients were within the tolerance ellipses. The real part of the impedance in thorax region can identify over-hydrated patients with an increased risk for cardiovascular disease associate to hypertension. Multi-frequency bioimpedance measurement show an important change at low and high frequency and indicate that is possible to obtain more information about extra-cellular or intra-cellular fluid status, to find the relation between fluid loads, bioimpedance parameters, extra-cellular water, and blood pressure.

Entities:  

Mesh:

Year:  2007        PMID: 18002774     DOI: 10.1109/IEMBS.2007.4353108

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  2 in total

1.  Association of bioimpedance spectroscopy-based volume estimation with postdialysis hypotension in patients receiving hemodialysis.

Authors:  Adrian P Abreo; Glenn M Chertow; Lorien S Dalrymple; George A Kaysen; Kirsten L Johansen
Journal:  Hemodial Int       Date:  2015-04-16       Impact factor: 1.812

2.  Towards personalized fluid monitoring in haemodialysis patients: thoracic bioimpedance signal shows strong correlation with fluid changes, a cohort study.

Authors:  Melanie K Schoutteten; Julie Vranken; Seulki Lee; Christophe J P Smeets; Hélène De Cannière; Chris Van Hoof; Jacques Peeters; Willemijn Groenendaal; Pieter M Vandervoort
Journal:  BMC Nephrol       Date:  2020-07-11       Impact factor: 2.388

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.