Literature DB >> 18002288

Feasibility of heart rate variability measurement from quadrature Doppler radar using arctangent demodulation with DC offset compensation.

Wansuree Massagram1, Noah M Hafner, Byung-Kwan Park, Victor M Lubecke, Anders Host-Madsen, Olga Boric-Lubecke.   

Abstract

This paper describes the experimental results of the beat-to-beat interval measurement from a quadrature Doppler radar system utilizing arctangent demodulation with DC offset compensation techniques. The comparison in SDNN and in RMSDD of both signals demonstrates the potential of using quadrature Doppler radar for HRV analysis.

Mesh:

Year:  2007        PMID: 18002288     DOI: 10.1109/IEMBS.2007.4352622

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  6 in total

1.  Contact and Remote Breathing Rate Monitoring Techniques: A Review.

Authors:  Mohamed Ali; Ali Elsayed; Arnaldo Mendez; Yvon Savaria; Mohamad Sawan
Journal:  IEEE Sens J       Date:  2021-04-12       Impact factor: 4.325

2.  A Doppler Radar System for Sensing Physiological Parameters in Walking and Standing Positions.

Authors:  Malikeh Pour Ebrahim; Majid Sarvi; Mehmet Rasit Yuce
Journal:  Sensors (Basel)       Date:  2017-03-01       Impact factor: 3.576

3.  A new principle of pulse detection based on terahertz wave plethysmography.

Authors:  Yu Rong; Panagiotis C Theofanopoulos; Georgios C Trichopoulos; Daniel W Bliss
Journal:  Sci Rep       Date:  2022-04-15       Impact factor: 4.379

4.  Non-Contact Detection of Vital Signs Based on Improved Adaptive EEMD Algorithm (July 2022).

Authors:  Didi Xu; Weihua Yu; Changjiang Deng; Zhongxia Simon He
Journal:  Sensors (Basel)       Date:  2022-08-25       Impact factor: 3.847

5.  Algoritmically improved microwave radar monitors breathing more acurrate than sensorized belt.

Authors:  Andrzej Czyżewski; Bozena Kostek; Adam Kurowski; Krzysztof Narkiewicz; Beata Graff; Piotr Odya; Tomasz Śmiałkowski; Andrzej Sroczyński
Journal:  Sci Rep       Date:  2022-08-24       Impact factor: 4.996

6.  Automated Detection of Sleep Apnea-Hypopnea Events Based on 60 GHz Frequency-Modulated Continuous-Wave Radar Using Convolutional Recurrent Neural Networks: A Preliminary Report of a Prospective Cohort Study.

Authors:  Jae Won Choi; Dong Hyun Kim; Dae Lim Koo; Yangmi Park; Hyunwoo Nam; Ji Hyun Lee; Hyo Jin Kim; Seung-No Hong; Gwangsoo Jang; Sungmook Lim; Baekhyun Kim
Journal:  Sensors (Basel)       Date:  2022-09-21       Impact factor: 3.847

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.