Literature DB >> 18002234

Comparison of three spike detectors dedicated to single unit action potentials of the auditory nerve.

J Bourien1, J Ruel, L Senhadji, J L Puel.   

Abstract

This paper compares three methods for the detection of single unit action potentials in auditory nerve. The detector structures are similar consisting of a filtering procedure in the first stage and a decision rule in the second stage. The detection accuracy of each detector is characterized by the couple probability of a true detection vs. rates of false detection with synthetic data. The performance comparison between detectors shows that the detector using a band-pass finite-impulse-response filter with complex coefficients offers the best performance. This observation was especially evident for low signal to noise ratios. This finding is confirmed with real data and leads us to revise the protocol of spike detection in auditory nerve.

Mesh:

Year:  2007        PMID: 18002234     DOI: 10.1109/IEMBS.2007.4352568