Literature DB >> 18002011

Shoulder motion analysis using simultaneous skin shape registration.

C Schwartz1, M Lempereur, V Burdin, J J Jacq, O Rémy-Néris.   

Abstract

A new non-invasive approach is proposed to study joint motions. It is based on dynamic tracking of the skin shape. A robust simultaneous registration algorithm (Iterative Median Closest Point) is used to follow the evolving shape and compute the rigid motion of the underlying bone structures. This new method relies on the differentiation of the rigid and elastic parts of the shape motion. A skin marker network is tracked by a set of infrared cameras. Unlike usual techniques, the algorithm tracks the instantaneous polyhedral shape embedding this network. This innovating approach is expected to minimize bias effect of skin sweeps and give some new information about the underlying soft tissue activities. Current application addresses the motion of the shoulder complex (humerus, clavicle and scapula). It is compared with two marker-based methods published in the literature. Preliminary results show significant differences between these three approaches. The new approach measurements give rise to greater rotations.

Entities:  

Mesh:

Year:  2007        PMID: 18002011      PMCID: PMC2686220          DOI: 10.1109/IEMBS.2007.4352345

Source DB:  PubMed          Journal:  Annu Int Conf IEEE Eng Med Biol Soc        ISSN: 2375-7477


  19 in total

1.  Correcting for deformation in skin-based marker systems.

Authors:  E J Alexander; T P Andriacchi
Journal:  J Biomech       Date:  2001-03       Impact factor: 2.712

2.  Evaluation of the global optimisation method within the upper limb kinematics analysis.

Authors:  E Roux; S Bouilland; A-P Godillon-Maquinghen; D Bouttens
Journal:  J Biomech       Date:  2002-09       Impact factor: 2.712

Review 3.  ISB recommendation on definitions of joint coordinate systems of various joints for the reporting of human joint motion--Part II: shoulder, elbow, wrist and hand.

Authors:  Ge Wu; Frans C T van der Helm; H E J DirkJan Veeger; Mohsen Makhsous; Peter Van Roy; Carolyn Anglin; Jochem Nagels; Andrew R Karduna; Kevin McQuade; Xuguang Wang; Frederick W Werner; Bryan Buchholz
Journal:  J Biomech       Date:  2005-05       Impact factor: 2.712

4.  Deviation of skin marker from bone target during movement of the scapula.

Authors:  Kazuhisa Matsui; Kazushi Shimada; Paul D Andrew
Journal:  J Orthop Sci       Date:  2006-03       Impact factor: 1.601

5.  Performing accurate joint kinematics from 3-D in vivo image sequences through consensus-driven simultaneous registration.

Authors:  Jean-José Jacq; Thierry Cresson; Valérie Burdin; Christian Roux
Journal:  IEEE Trans Biomed Eng       Date:  2008-05       Impact factor: 4.538

6.  Determining the movements of the skeleton using well-configured markers.

Authors:  I Söderkvist; P A Wedin
Journal:  J Biomech       Date:  1993-12       Impact factor: 2.712

7.  A least-squares algorithm for the equiform transformation from spatial marker co-ordinates.

Authors:  F E Veldpaus; H J Woltring; L J Dortmans
Journal:  J Biomech       Date:  1988       Impact factor: 2.712

8.  A solidification procedure to facilitate kinematic analyses based on video system data.

Authors:  L Chèze; B J Fregly; J Dimnet
Journal:  J Biomech       Date:  1995-07       Impact factor: 2.712

Review 9.  Human movement analysis using stereophotogrammetry. Part 3. Soft tissue artifact assessment and compensation.

Authors:  Alberto Leardini; Lorenzo Chiari; Ugo Della Croce; Aurelio Cappozzo
Journal:  Gait Posture       Date:  2005-02       Impact factor: 2.840

10.  Glenohumeral relationships during physiologic shoulder motion and stress testing: initial experience with open MR imaging and active imaging-plane registration.

Authors:  C F Beaulieu; D K Hodge; A G Bergman; K Butts; B L Daniel; C L Napper; R D Darrow; C L Dumoulin; R J Herfkens
Journal:  Radiology       Date:  1999-09       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.