Literature DB >> 18001360

Comparison of accuracy of aortic valve area assessment in aortic stenosis by real time three-dimensional echocardiography in biplane mode versus two-dimensional transthoracic and transesophageal echocardiography.

Nathalie Blot-Souletie1, Aurélien Hébrard, Philippe Acar, Didier Carrié, Jacques Puel.   

Abstract

Our aim was to validate the clinical feasibility of assessment of the area of the aortic valve orifice (AVA) by real time three-dimensional echocardiography (RT3DE) in biplane mode by planimetry and to compare it with the echo-Doppler methods more commonly used to evaluate valvular aortic stenosis (AS).RT3DE in biplane mode is a novel technique that allows operators to visualize the aortic valve orifice anatomy in any desired plane orientation. Its usefulness and accuracy have not previously been established. Using this technique, we studied a series of patients with AS and compared the results with those obtained by two-dimensional transesophageal echocardiography (TEE) planimetry and two-dimensional transthoracic echocardiography using the continuity equation (TTE-CE). RT3DE planimetries in biplane mode were measured by two independent observers. Bland-Altman analysis was used to compare these two methods.Forty-one patients with AS were enrolled in the study (15 women, 26 men, mean age 73.5 +/- 8.2 years). RT3DE planimetry was feasible in 92.7%. Average AVA determined by TTE-CE was 0.76 +/- 0.20 cm, by TEE planimetry 0.73 +/- 0.1 cm, and by RT3DE planimetry 0.76 +/- 0.20 cm(2). The average differences in AVA were-0.001 +/- 0.254 cm(2) and 0.03 +/- 0.155 cm(2) (RT3DE/TEE). The correlation coefficient for AVA (RT3DE/TTE-CE) was 0.82 and for AVA (RT3DE/TEE) it was 0.94, P < 0.0001. No significant intra- and interobserver variability was observed. In conclusion, RT3DE in biplane mode provides a feasible and reproducible method for measuring the area of the aortic valve orifice in aortic stenosis.

Entities:  

Mesh:

Year:  2007        PMID: 18001360     DOI: 10.1111/j.1540-8175.2007.00526.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  1 in total

1.  Feasibility of in vivo human aortic valve modeling using real-time three-dimensional echocardiography.

Authors:  Arminder S Jassar; Melissa M Levack; Ricardo D Solorzano; Alison M Pouch; Giovanni Ferrari; Albert T Cheung; Victor A Ferrari; Joseph H Gorman; Robert C Gorman; Benjamin M Jackson
Journal:  Ann Thorac Surg       Date:  2014-02-08       Impact factor: 4.330

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.