Epidural puncture can be confirmed by the Queckenstedt-test procedure in patients with cervical spinal canal stenosis.

T Yokoyama1, T Ushida, F Yamasaki, S Inoue, K A Sluka.   

Abstract

BACKGROUND: The loss-of-resistance test is the most popular method for identifying the epidural space, but it cannot confirm epidural puncture. Therefore, we developed a new method to confirm epidural puncture by assessing indirect changes in epidural pressure using the Queckenstedt-test procedure, which increases subarachnoid pressure by compressing the internal jugular veins. Because this new method depends on the dynamics of cerebrospinal fluid, blockade of cerebrospinal fluid flow, as with severe spinal stenosis, is predicted to reduce changes in epidural pressure. Thus, in this study, we examined the effect of spinal stenosis on the Queckenstedt-test procedure.
METHODS: Epidural puncture using the loss-of-resistance test was utilized to insert an electrode in patients undergoing cervical spine surgery. Epidural pressure was monitored during bilateral compression of the internal jugular veins to confirm epidural puncture. The insertion of the electrode into the epidural space was confirmed by observation of muscle twitch evoked by electric stimulation.
RESULTS: In 60 patients, epidural puncture was performed with the loss-of-resistance test; a second trial was required in 13 patients. Increased epidural pressure was observed in 57/73 trials. When increased epidural pressure was observed, epidural puncture was always successful. The sensitivity and specificity of this method was 92.0% and 100%, respectively. The positive and negative predictive values were 100% and 66.7%, respectively.
CONCLUSION: An increase in epidural pressure during bilateral compression of the internal jugular veins could offer a reliable method for confirming epidural puncture in combination with the loss-of-resistance test, even if patients have potential spinal canal narrowing.

Entities:  

Mesh:

Year:  2007        PMID: 17999711     DOI: 10.1111/j.1399-6576.2007.01506.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  3 in total

1.  Epidural catheter malposition in a failed epidural anesthesia confirmed by computed tomography.

Authors:  Se Jin Lee; Sang Ho Kim; Sun Young Park; Mun Gyu Kim; Bo Il Jung; Si Young Ok
Journal:  Korean J Pain       Date:  2011-02-25

2.  Spreading pattern of contrast medium in the high thoracic epidural space in rabbits: the effect of neck flexion and extension.

Authors:  Mi-Hyun Kim; Young Jin Lim; Deok-Man Hong; Yun-Seok Jeon; Hee Pyoung Park; Young-Tae Jeon; Soon Young Shin; Sun Sook Han
Journal:  Korean J Anesthesiol       Date:  2010-08-20

Review 3.  Etiology and use of the "hanging drop" technique: a review.

Authors:  Ludmil Todorov; Timothy VadeBoncouer
Journal:  Pain Res Treat       Date:  2014-04-15