Literature DB >> 17999004

Enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements: comparison of a new device with hand-held dynamometry.

Tung-Wu Lu1, Horng-Chaung Hsu, Ling-Ying Chang, Hao-Ling Chen.   

Abstract

OBJECTIVE: To develop and determine the reliability of a newly -designed resistance-enhanced dynamometer for muscle strength measurement, and to test the hypothesis that enhancing the examiner's resisting force improves the reliability of manual muscle strength measurements.
DESIGN: An intra-examiner, inter-examiner, intra-session and inter-session reliability study.
SUBJECTS: Twenty-five men (mean age 22.5 (standard deviation (SD) 1.7) years) were tested separately by 2 examiners using the resistance-enhanced dynamometer and a traditional hand-held dynamometer for an intra- and inter-examiner reliability study. Twenty-seven volunteers (mean age 22.1 (SD 0.8) years) were tested by a female examiner using the resistance-enhanced dynamometer for an intra- and inter-session reliability study.
METHODS: Maximum resisting forces for the knee flexors and extensors were measured using the resistance-enhanced dynamometer and the traditional hand-held dynamometer.
RESULTS: The traditional hand-held dynamometer had good intra-examiner reliability (intra-class correlation coefficient (ICC) = 0.79-0.93) but poor inter-examiner reliability (ICC = 0.11-0.28). The resistance-enhanced dynamo meter had very good intra-examiner (ICC = 0.91-0.94), inter-examiner (ICC = 0.98), intra-session (ICC = 0.93-0.99) and inter-session (ICC = 0.91-0.92) reliability. The resistance-enhanced dynamometer also had better inter-examiner agreement (smallest real difference (SRD) 9-16% for resistance-enhanced dynamometer, 21-43% for traditional hand-held dynamometer).
CONCLUSION: The resistance-enhanced dynamometer had very good reliability. Enhancing the examiner's resisting force appeared to improve the reliability of manual muscle strength measurements. The resistance-enhanced dynamometer is useful for muscle strength measurements in clinical practice.

Entities:  

Mesh:

Year:  2007        PMID: 17999004     DOI: 10.2340/16501977-0107

Source DB:  PubMed          Journal:  J Rehabil Med        ISSN: 1650-1977            Impact factor:   2.912


  16 in total

1.  Reliability of maximal isometric knee strength testing with modified hand-held dynamometry in patients awaiting total knee arthroplasty: useful in research and individual patient settings? A reliability study.

Authors:  Ian F H Koblbauer; Yannick Lambrecht; Micheline L M van der Hulst; Camille Neeter; Raoul H H Engelbert; Rudolf W Poolman; Vanessa A Scholtes
Journal:  BMC Musculoskelet Disord       Date:  2011-10-31       Impact factor: 2.362

2.  Reliability of measurements of knee extensor muscle strength using a pull-type hand-held dynamometer.

Authors:  Terumi Suzuki
Journal:  J Phys Ther Sci       Date:  2015-03-31

3.  Validity of maximal isometric knee extension strength measurements obtained via belt-stabilized hand-held dynamometry in healthy adults.

Authors:  Naoko Ushiyama; Yasushi Kurobe; Kimito Momose
Journal:  J Phys Ther Sci       Date:  2017-11-24

4.  A Maximum Muscle Strength Prediction Formula Using Theoretical Grade 3 Muscle Strength Value in Daniels et al.'s Manual Muscle Test, in Consideration of Age: An Investigation of Hip and Knee Joint Flexion and Extension.

Authors:  Hideyuki Usa; Masashi Matsumura; Kazuna Ichikawa; Hitoshi Takei
Journal:  Rehabil Res Pract       Date:  2017-01-04

5.  Reliability and Validity of a Novel Wearable Device for Measuring Elbow Strength.

Authors:  Marcus Brookshaw; Andrew Sexton; Chris A McGibbon
Journal:  Sensors (Basel)       Date:  2020-06-17       Impact factor: 3.576

6.  Hand-held dynamometry in patients with haematological malignancies: measurement error in the clinical assessment of knee extension strength.

Authors:  Ruud H Knols; Geert Aufdemkampe; Eling D de Bruin; Daniel Uebelhart; Neil K Aaronson
Journal:  BMC Musculoskelet Disord       Date:  2009-03-09       Impact factor: 2.362

7.  Reliability of a new stabilized dynamometer system for the evaluation of hip strength.

Authors:  Timothy W Tourville; Helen C Smith; Sandra J Shultz; Pamela M Vacek; James R Slauterbeck; Robert J Johnson; Bruce D Beynnon
Journal:  Sports Health       Date:  2013-03       Impact factor: 3.843

8.  The effects of spinal mobilization with arm movements on shoulder muscle strengthening.

Authors:  Youngjoon Seo; Jaeseok Lee; Dongwook Han
Journal:  J Phys Ther Sci       Date:  2015-01-09

9.  Absolute Reliability and Concurrent Validity of Hand Held Dynamometry and Isokinetic Dynamometry in the Hip, Knee and Ankle Joint: Systematic Review and Meta-analysis.

Authors:  Claudio Chamorro; Susan Armijo-Olivo; Carlos De la Fuente; Javiera Fuentes; Luis Javier Chirosa
Journal:  Open Med (Wars)       Date:  2017-10-17

10.  Surgical Intervention for Spastic Upper Extremity Improves Lower Extremity Kinematics in Spastic Adults: A Collection of Case Studies.

Authors:  Nojoud AlHakeem; Elizabeth Anne Ouellette; Francesco Travascio; Shihab Asfour
Journal:  Front Bioeng Biotechnol       Date:  2020-02-21
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.