Literature DB >> 1799787

A 5-year experience with 307 CT-guided renal biopsies: results and complications.

M Sateriale1, J J Cronan, L D Savadler.   

Abstract

Three hundred four patients with diffuse renal disease underwent 307 consecutive percutaneous biopsies with use of nonenhanced computed tomographic (CT) guidance and the 14-gauge Vim Silverman needle. Satisfactory tissue for histopathologic diagnosis was obtained in 100% of cases. Precise data collection before and after the last 241 biopsies enabled diagnosis of 18 hemorrhagic complications (7.5%). The conditions of five patients stabilized without intervention. Thirteen patients received blood transfusions, and one required therapeutic embolization. One death occurred in a patient with advanced systemic lupus erythematosus. Two nonhemorrhagic complications were fevers after biopsy, both of which resolved without sequelae. Review of medical records revealed increased hemorrhagic complication rates in dialysis patients, female patients, patients who underwent left-sided biopsies, and patients pretreated with 1-deamino-8-D-arginine vasopressin to reverse uremic platelet dysfunction. No complications were associated with biopsies in 14 pediatric patients (younger than 16 years) and 10 renal transplant recipients. Risk of hemorrhagic complications had no correlation with patient age (when older than age 16 years) and 10 renal transplant recipients. Risk of hemorrhagic complications had no correlation with patient age (when older than age 16 years), creatinine level, hematocrit, pathologic features of resultant biopsy specimen, or whether the patient was admitted solely for the biopsy.

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1799787     DOI: 10.1016/s1051-0443(91)72272-0

Source DB:  PubMed          Journal:  J Vasc Interv Radiol        ISSN: 1051-0443            Impact factor:   3.464


  3 in total

Review 1.  The Native Kidney Biopsy: Update and Evidence for Best Practice.

Authors:  Jonathan J Hogan; Michaela Mocanu; Jeffrey S Berns
Journal:  Clin J Am Soc Nephrol       Date:  2015-09-02       Impact factor: 8.237

Review 2.  Alternative renal biopsies: past and present.

Authors:  Li Zhuo; Haifeng Wang; Dapeng Chen; Haitao Lu; Guming Zou; Wenge Li
Journal:  Int Urol Nephrol       Date:  2017-07-29       Impact factor: 2.370

3.  A new method of kidney biopsy using low dose CT-guidance with coaxial trocar and bard biopsy gun.

Authors:  Xiao-Ling Pi; Zhen Tang; Li-Qian Fu; Mei-Hua Guo; Mei-Hua Shi; Lan Chen; Zheng-Ying Wan
Journal:  Biol Proced Online       Date:  2013-01-07       Impact factor: 3.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.