Revisiting the sigmoidal curve fitting applied to quantitative real-time PCR data.

Stéphane Swillens1, Barbara Dessars, Hakim El Housni.   

Abstract

Amplification of a cDNA product by quantitative polymerase chain reaction (qPCR) gives rise to fluorescence sigmoidal curves from which absolute or relative target gene content of the sample is inferred. Besides comparative C(t) methods that require the construction of a reference standard curve, other methods that focus on the analysis of the sole amplification curve have been proposed more recently. Among them, the so-called sigmoidal curve fitting (SCF) method rests on the fitting of an empirical sigmoidal model to the experimental amplification data points, leading to the prediction of the amplification efficiency and to the calculation of the initial copy number in the sample. The implicit assumption of this method is that the sigmoidal model may describe an amplification curve quantitatively even in the portion of the curve where the fluorescence signal is hidden in the noise band. The theoretical basis of the SCF method was revisited here for defining the class of experimental amplification curves for which the method might be relevant. Applying the SCF method to six well-characterized different PCR assays illustrated possible pitfalls leading to biased estimates of the amplification efficiency and, thus, of the target gene content of a sample.

Mesh:

Substances:

Year:  2007        PMID: 17996715     DOI: 10.1016/j.ab.2007.10.019

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  10 in total

1.  Efficient experimental design and analysis of real-time PCR assays.

Authors:  Kwokyin Hui; Zhong-Ping Feng
Journal:  Channels (Austin)       Date:  2013-03-19       Impact factor: 2.581

2.  Cryptosporidium parvum Elongation Factor 1α Participates in the Formation of Base Structure at the Infection Site During Invasion.

Authors:  Xue Yu; Fengguang Guo; Rola Barhoumi Mouneimne; Guan Zhu
Journal:  J Infect Dis       Date:  2020-05-11       Impact factor: 5.226

3.  An improvement of the 2ˆ(-delta delta CT) method for quantitative real-time polymerase chain reaction data analysis.

Authors:  Xiayu Rao; Xuelin Huang; Zhicheng Zhou; Xin Lin
Journal:  Biostat Bioinforma Biomath       Date:  2013-08

4.  A novel data processing method CyC* for quantitative real time polymerase chain reaction minimizes cumulative error.

Authors:  Linzhong Zhang; Rui Dong; Shu Wei; Han-Chen Zhou; Meng-Xian Zhang; Karthikeyan Alagarsamy
Journal:  PLoS One       Date:  2019-06-11       Impact factor: 3.240

5.  Loop-mediated isothermal amplification-based electrochemical sensor for detecting SARS-CoV-2 in wastewater samples.

Authors:  Roberto G Ramírez-Chavarría; Elizabeth Castillo-Villanueva; Bryan E Alvarez-Serna; Julián Carrillo-Reyes; Rosa María Ramírez-Zamora; Germán Buitrón; Luis Alvarez-Icaza
Journal:  J Environ Chem Eng       Date:  2022-02-28

6.  Amplification efficiency: linking baseline and bias in the analysis of quantitative PCR data.

Authors:  J M Ruijter; C Ramakers; W M H Hoogaars; Y Karlen; O Bakker; M J B van den Hoff; A F M Moorman
Journal:  Nucleic Acids Res       Date:  2009-02-22       Impact factor: 16.971

7.  Accurate estimation of nucleic acids by amplification efficiency dependent PCR.

Authors:  Nilanjana Chatterjee; Tanmay Banerjee; Santanu Datta
Journal:  PLoS One       Date:  2012-08-17       Impact factor: 3.240

8.  Simultaneous detection and differentiation of human papillomavirus genotypes 6, 11, 16 and 18 by AllGlo quadruplex quantitative PCR.

Authors:  Daojun Yu; Yu Chen; Shenghai Wu; Baohong Wang; Yi-Wei Tang; Lanjuan Li
Journal:  PLoS One       Date:  2012-11-09       Impact factor: 3.240

9.  A kinetic-based sigmoidal model for the polymerase chain reaction and its application to high-capacity absolute quantitative real-time PCR.

Authors:  Robert G Rutledge; Don Stewart
Journal:  BMC Biotechnol       Date:  2008-05-08       Impact factor: 2.563

10.  Critical evaluation of methods used to determine amplification efficiency refutes the exponential character of real-time PCR.

Authors:  Robert G Rutledge; Don Stewart
Journal:  BMC Mol Biol       Date:  2008-10-30       Impact factor: 2.946

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.