Receiver operating characteristic and location analysis of simulated near-infrared tomography images.

Xiaomei Song1, Brian W Pogue, Hamid Dehghani, Shudong Jiang, Keith D Paulsen, Tor D Tosteson.   

Abstract

Receiver operating characteristic (ROC) analysis was performed on simulated near-infrared tomography images, using both human observer and contrast-to-noise ratio (CNR) computational assessment, for application in breast cancer imaging. In the analysis, a nonparametric approach was applied for estimating the ROC curves. Human observer detection of objects had superior capability to localize the presence of heterogeneities when the objects were small with high contrast, with a minimum detectable threshold of CNR near 3.0 to 3.3 in the images. Human observers were able to detect heterogeneities in the images below a size limit of 4 mm, yet could not accurately find the location of these objects when they were below 10 mm diameter. For large objects, the lower limit of a detectable contrast limit was near 10% increase relative to the background. The results also indicate that iterations of the nonlinear reconstruction algorithm beyond 4 did not significantly improve the human detection ability, and degraded the overall localization ability for the objects in the image, predominantly by increasing the noise in the background. Interobserver variance performance in detecting objects in these images was low, suggesting that because of the low spatial resolution, detection tasks with NIR tomography is likely consistent between human observers.

Entities:  

Mesh:

Year:  2007        PMID: 17994901     DOI: 10.1117/1.2799197

Source DB:  PubMed          Journal:  J Biomed Opt        ISSN: 1083-3668            Impact factor:   3.170


  3 in total

1.  Computer-aided diagnosis of rheumatoid arthritis with optical tomography, Part 1: feature extraction.

Authors:  Ludguier D Montejo; Jingfei Jia; Hyun K Kim; Uwe J Netz; Sabine Blaschke; Gerhard A Müller; Andreas H Hielscher
Journal:  J Biomed Opt       Date:  2013-07       Impact factor: 3.170

2.  Automatic exposure control and estimation of effective system noise in diffuse fluorescence tomography.

Authors:  Dax L Kepshire; Hamid Dehghani; Frederic Leblond; Brian W Pogue
Journal:  Opt Express       Date:  2009-12-07       Impact factor: 3.894

3.  Diagnostic detection of diffuse glioma tumors in vive with molecular fluorescent probe-based transmission spectroscopy.

Authors:  Summer L Gibbs-Strauss; Julia A O'Hara; Subhadra Srinivasan; P Jack Hoopes; Tayyaba Hasan; Brian W Pogue
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.