Literature DB >> 17994133

Common-path interferometric detection of protein monolayer on the BioCD.

Xuefeng Wang1, Ming Zhao, D D Nolte.   

Abstract

The bio-optical compact disk (BioCD) is an optical biosensor that performs common-path molecular interferometry of patterned proteins on a disk spinning at high speed. The common-path configuration makes it ultrastable and allows surface height precision below 10 pm. In this paper we show that two complementary interferometric quadrature conditions exist simultaneously that convert the modulus and phase of the reflection coefficient, modulated by protein patterns on the disk surface, into intensity modulation at the detector. In the far field they separate into spatially symmetric and antisymmetric intensity modulation in response to the local distribution of protein. The antisymmetric response is equivalent to differential phase-contrast detection, and the symmetric response is equivalent to in-line (IL) common-path interferometry. We measure the relative sensitivities of these orthogonal channels to printed protein patterns on disk structures that include thermal oxide on silicon and Bragg dielectric stacks. The scaling mass sensitivity of the IL channel on oxide on silicon was measured to be 0.17 pg/mm.

Entities:  

Year:  2007        PMID: 17994133     DOI: 10.1364/ao.46.007836

Source DB:  PubMed          Journal:  Appl Opt        ISSN: 1559-128X            Impact factor:   1.980


  7 in total

Review 1.  Invited Review Article: Review of centrifugal microfluidic and bio-optical disks.

Authors:  David D Nolte
Journal:  Rev Sci Instrum       Date:  2009-10       Impact factor: 1.523

2.  Molecular layer detection on a diffractive optical balance.

Authors:  Xuefeng Wang; Ming Zhao; David D Nolte
Journal:  Opt Lett       Date:  2012-10-01       Impact factor: 3.776

3.  Ambient molecular water accumulation on silica surfaces detected by a reflectance interference optical balance.

Authors:  Xuefeng Wang; Ming Zhao; David D Nolte
Journal:  Appl Phys Lett       Date:  2010-11-03       Impact factor: 3.791

4.  Prostate specific antigen detection in patient sera by fluorescence-free BioCD protein array.

Authors:  Xuefeng Wang; Ming Zhao; David D Nolte; Timothy L Ratliff
Journal:  Biosens Bioelectron       Date:  2010-02-20       Impact factor: 10.618

5.  Mass-transport limitations in spot-based microarrays.

Authors:  Ming Zhao; Xuefeng Wang; David Nolte
Journal:  Biomed Opt Express       Date:  2010-09-20       Impact factor: 3.732

6.  Height Resolution of Antibody Spots Measured by Spinning-Disk Interferometry on the BioCD.

Authors:  Kevin O'Brien; Ming Zhao; David Nolte
Journal:  Micromachines (Basel)       Date:  2016-02-17       Impact factor: 2.891

7.  Common-path interferometer for digital holographic Doppler spectroscopy of living biological tissues.

Authors:  Kwan Jeong; Maria Josef Lopera; John Turek; David Nolte
Journal:  J Biomed Opt       Date:  2021-03       Impact factor: 3.170

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.