Literature DB >> 17991506

A Legionnaires' disease outbreak: a water blaster and roof-collected rainwater systems.

Greg Simmons1, Sheryl Jury, Craig Thornley, David Harte, Jasmine Mohiuddin, Michael Taylor.   

Abstract

In February 2006, an outbreak of Legionnaires' disease (LD) was identified in Beachlands, a small, isolated east Auckland suburb. It was investigated through case finding, a case-control study, sampling potential sources of infection and by molecular typing (using sequence-based typing (SBT) of all Legionella pneumophila serogroup 1 (Lp1) isolates). Lp1 was isolated from the respiratory tract of one case, the roof-collected rainwater systems of five households (three associated with cases) and from a water blaster at a nearby marina. All isolates were indistinguishable, exhibiting the same SBT allele pattern. Three LD cases lived within 500m of the water blaster (the fourth case within 1250m) and downwind in prevailing conditions. Another domestic roof-collected rainwater supply contaminated by Lp1 (identical SBT pattern) was incidentally identified in another suburb 4km east of Beachlands. This is the first outbreak of LD linked to roof-collected rainwater supplies and the first isolation of Legionella from these systems in New Zealand. Aerosols containing Legionella discharged to air by the marina water blaster may have infected some cases directly or may have seeded roof-collected rainwater systems. Some cases may have been exposed by contaminated bathroom showers. Roof-collected rainwater systems need appropriate design, careful cleaning and the maintenance of hot water temperatures at a minimum of 60 degrees C to reduce the chances of Legionella multiplying. Further research into the ecology of Legionella in roof-collected rain water systems is indicated.

Entities:  

Mesh:

Year:  2007        PMID: 17991506     DOI: 10.1016/j.watres.2007.10.016

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  8 in total

1.  Presence of microbial and chemical source tracking markers in roof-harvested rainwater and catchment systems for the detection of fecal contamination.

Authors:  M Waso; T Ndlovu; P H Dobrowsky; S Khan; W Khan
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-20       Impact factor: 4.223

2.  Abundance of Naegleria fowleri in roof-harvested rainwater tank samples from two continents.

Authors:  Monique Waso; Penelope Heather Dobrowsky; Kerry Ann Hamilton; Geoffrey Puzon; Haylea Miller; Wesaal Khan; Warish Ahmed
Journal:  Environ Sci Pollut Res Int       Date:  2017-12-11       Impact factor: 4.223

3.  Health risk from the use of roof-harvested rainwater in Southeast Queensland, Australia, as potable or nonpotable water, determined using quantitative microbial risk assessment.

Authors:  W Ahmed; A Vieritz; A Goonetilleke; T Gardner
Journal:  Appl Environ Microbiol       Date:  2010-09-17       Impact factor: 4.792

4.  Ten Questions Concerning the Aerosolization and Transmission of Legionella in the Built Environment.

Authors:  Aaron J Prussin; David Otto Schwake; Linsey C Marr
Journal:  Build Environ       Date:  2017-06-13       Impact factor: 6.456

5.  An unusually long-lasting outbreak of community-acquired Legionnaires' disease, 2005-2008, Italy.

Authors:  M Scaturro; S Fontana; S Crippa; M G Caporali; T Seyler; E Veschetti; G Villa; M C Rota; M L Ricci
Journal:  Epidemiol Infect       Date:  2014-11-27       Impact factor: 4.434

6.  Molecular detection of Acanthamoeba spp., Naegleria fowleri and Vermamoeba (Hartmannella) vermiformis as vectors for Legionella spp. in untreated and solar pasteurized harvested rainwater.

Authors:  Penelope H Dobrowsky; Sehaam Khan; Thomas E Cloete; Wesaal Khan
Journal:  Parasit Vectors       Date:  2016-10-10       Impact factor: 3.876

7.  GVPC Medium Manufactured without Oxygen Improves the Growth of Legionella spp. and Exhibits Enhanced Selectivity Properties.

Authors:  Pablo Casino; Asunción López; Sara Peiró; Martín Ríos; Santiago Ríos; Aldous Porta; Gemma Agustí; Daniel Asensio; Ana María Marqués; Núria Piqué
Journal:  Microbiol Spectr       Date:  2022-03-22

Review 8.  Legionella Occurrence beyond Cooling Towers and Premise Plumbing.

Authors:  David Otto Schwake; Absar Alum; Morteza Abbaszadegan
Journal:  Microorganisms       Date:  2021-12-09
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.