Microstructure and wear properties of LENS deposited medical grade CoCrMo.

G D Janaki Ram1, C K Esplin, B E Stucker.   

Abstract

There is a growing interest in metal-on-metal bearing surfaces for orthopedic implants. Although some success has been achieved in applications like hip implants which involve a large contact area, non-conforming joints, such as knees, have proved more difficult. The current work examines the applicability of a novel additive manufacturing process, Laser Engineered Net Shaping (LENS), the registered trademark and service mark of Sandia National Laboratories and Sandia Corporation), for producing CoCrMo implants. A series of experiments were conducted to determine the optimum parameters for deposition of CoCrMo. Microstructural studies, hardness tests, and dry sand/rubber wheel abrasive wear tests were conducted on the LENS deposits. The results showed that metallurgically sound deposits can be produced using the LENS process under optimized conditions. The hardness of the LENS deposited CoCrMo was found to be comparable to that of standard CoCrMo wrought material; however, wear tests indicated that LENS deposits were considerably less resistant to abrasive wear than wrought CoCrMo. The reasons for this behaviour are discussed based on microstructural observations.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17990083     DOI: 10.1007/s10856-007-3078-6

Source DB:  PubMed          Journal:  J Mater Sci Mater Med        ISSN: 0957-4530            Impact factor:   3.896


  3 in total

1.  Comparison of alloys and designs in a hip simulator study of metal on metal implants.

Authors:  J B Medley; F W Chan; J J Krygier; J D Bobyn
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

Review 2.  Factors correlating with long term survival of McKee-Farrar total hip prostheses.

Authors:  T P Schmalzried; E S Szuszczewicz; K H Akizuki; T D Petersen; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

Review 3.  Mechanism and clinical significance of wear debris-induced osteolysis.

Authors:  H C Amstutz; P Campbell; N Kossovsky; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1992-03       Impact factor: 4.176

  3 in total
  4 in total

1.  Additive manufacturing of biomaterials.

Authors:  Susmita Bose; Dongxu Ke; Himanshu Sahasrabudhe; Amit Bandyopadhyay
Journal:  Prog Mater Sci       Date:  2017-08-26

2.  Characterization of Co-Cr-W Dental Alloys with Veneering Materials Manufactured via Subtractive Milling and Additive Manufacturing LDED Methods.

Authors:  Óscar Barro; Felipe Arias-González; Fernando Lusquiños; Rafael Comesaña; Jesús Del Val; Antonio Riveiro; Aida Badaoui; Félix Gómez-Baño; Juan Pou
Journal:  Materials (Basel)       Date:  2022-06-30       Impact factor: 3.748

3.  Effect of heat treatment on the bio-corrosion properties and wear resistance of antibacterial Co-29Cr-6Mo-xCu alloys.

Authors:  Weiguo Li; Xiaoyan Wang; Cong Liu; Gaowu Qin; Erlin Zhang
Journal:  J Mater Sci Mater Med       Date:  2019-10-03       Impact factor: 3.896

Review 4.  Tribochemical Characterization and Tribocorrosive Behavior of CoCrMo Alloys: A Review.

Authors:  Wei Quan Toh; Xipeng Tan; Ayan Bhowmik; Erjia Liu; Shu Beng Tor
Journal:  Materials (Basel)       Date:  2017-12-26       Impact factor: 3.623