Ultrasound-guided fine needle aspiration biopsy of thyroid nodules performed in the office.

Kristin A Seiberling1, Jose C Dutra, James Gunn.   

Abstract

INTRODUCTION: The majority of thyroid fine needle aspiration biopsies (FNAB) today are performed in the office freehand by palpation. Not infrequently, patients are sent to radiology for an ultrasound-guided FNAB (USG-FNB). Real-time ultrasound (US) allows for continuous visualization of the needle during insertion and sampling. Historically, USG-FNAB has been a procedure performed by a radiologist in a designated radiology suite. In more recent years, with the development of smaller more portable US machines, there has been a push for clinicians other than radiologists to perform the procedure.
OBJECTIVE: To evaluate the accuracy and specimen adequacy of thyroid FNAB performed in the office under US guidance by one senior otolaryngologist.
METHODS: Retrospective chart review of 203 patients who underwent ultrasound-guided USG-FNA of the thyroid gland between September, 2005, to February, 2007, in the office setting by one senior otolaryngologist. Specimens were reviewed onsite at the time of biopsy for cellular adequacy by a cytotechnologist.
RESULTS: A total of 203 patients, 176 females and 27 males, underwent USG-FNA of the thyroid gland. The average age of the females was 52 years, and 59.4 years for the males. A total of 271 FNA biopsies were performed. Two hundred and twenty FNAB were satisfactory specimens (81.2%), 26 were unsatisfactory (9.6%), and 25 (9.2%) were limited due to blood clotting or hypocellularity. Of the FNA specimens that had enough cells to evaluate, 159 were benign, 48 were indeterminate for malignacy, and 13 were positive for malignancy. Of the nodules biopsied, 143 were greater than 1.5 cm (average 2.59 cm, unsatisfactory rate 12.6%), and 128 were less than 1.5 cm (average 1.21 cm, unsatisfactory rate 6.3%). In 44 patients, one or more nodule was biopsied at the same office visit. DISCUSSION: Thyroid US is an indispensable tool in the workup and diagnosis of thyroid disease. It may be used to help identify pathology and physical features suspicious for malignancy and guide FNAB of suspicious nodules. The availability of an office US machine allows the referring physician to perform a service that is normally done in a different department. This ultimately frees up time for both the patient and physician and reduces health care costs by eliminating extra office visits. More importantly, it allows the primary physician to be more knowledgeable and hands on with the patient's overall care.
CONCLUSION: This study shows that a trained physician may perform a USG-FNA of the thyroid gland in the office with results comparable to that in the radiology literature.

Entities:  

Mesh:

Year:  2008        PMID: 17989576     DOI: 10.1097/MLG.0b013e318157465d

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  10 in total

1.  Appropriate and accurate diagnosis of thyroid nodules: a review of thyroid fine-needle aspiration.

Authors:  Catherine Hambleton; Emad Kandil
Journal:  Int J Clin Exp Med       Date:  2013-06-26

2.  Use of ultrasound in the management of thyroid cancer.

Authors:  John I Lew; Carmen C Solorzano
Journal:  Oncologist       Date:  2010-03-09

Review 3.  Interventional radiology of the thyroid gland: critical review and state of the art.

Authors:  Antonio Barile; Simone Quarchioni; Federico Bruno; Anna Maria Ierardi; Francesco Arrigoni; Aldo Victor Giordano; Sergio Carducci; Marco Varrassi; Giampaolo Carrafiello; Ferdinando Caranci; Alessandra Splendiani; Ernesto Di Cesare; Carlo Masciocchi
Journal:  Gland Surg       Date:  2018-04

4.  Preoperative ultrasonography assessment of vocal cord movement during thyroid and parathyroid surgery: reply.

Authors:  Shih-Ping Cheng; Chien-Liang Liu
Journal:  World J Surg       Date:  2013-07       Impact factor: 3.352

Review 5.  A systematic review of ultrasound-guided FNA of lesions in the head and neck--focusing on operator, sample inadequacy and presence of on-spot cytology service.

Authors:  A Ganguly; G Burnside; P Nixon
Journal:  Br J Radiol       Date:  2014-09-23       Impact factor: 3.039

6.  Killian-Jamieson diverticulum mimicking a calcified thyroid nodule on ultrasonography: A case report and literature review.

Authors:  Li Cao; Junna Ge; Donghui Zhao; Shangtong Lei
Journal:  Oncol Lett       Date:  2016-08-10       Impact factor: 2.967

7.  Making mock-FNA smears from fresh surgical pathology specimens to improve smear preparation technique and to create cytohistological correlation series.

Authors:  Tibor Mezei; Anca Contac; Alina Iacob; Imre Egyed-Zsigmond
Journal:  PLoS One       Date:  2014-08-14       Impact factor: 3.240

8.  Comparison of 1869 thyroid ultrasound-guided fine-needle aspiration biopsies between general surgeons and interventional radiologists.

Authors:  Hilmi Bozkurt; Oktay İrkörücü; Mehmet Aziret; Enver Reyhan; Mehmet Kemal Okuyan
Journal:  Ann Med Surg (Lond)       Date:  2016-08-02

9.  Comparison of surgeon-performed ultrasound-guided fine needle aspiration cytology with histopathological diagnosis of thyroid nodules.

Authors:  Muhammad Ayoob Jat
Journal:  Pak J Med Sci       Date:  2019 Jul-Aug       Impact factor: 1.088

10.  Ultrasound-Guided Fine-Needle Biopsy of First 1000 Consecutive Thyroid Nodules: Single-Surgeon Experience.

Authors:  Jagdish K Dhingra
Journal:  OTO Open       Date:  2020-06-02
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.