Abstract

The limited number of self-monitoring blood glucose measurements is an obstacle for good metabolic control in patients with type 1 diabetes. However, continuous glucose measurement with real-time data and alarms is a recent technology that promises to improve the efficacy of treatment in diabetic patients. GuardianRT uses a continuous telemetry display of real-time glucose values, and automatic alerts at preset hypo- and hyperglycaemic levels. Three calibrations a day are required, and the sensor must be changed every three days. The GuardControl study showed that, within three months, real-time continuous glucose monitoring with the GuardianRT led to significantly improved HbA1c values in 162 poorly controlled patients (children and adults) with type 1 diabetes despite intensive insulin therapy. The continuous availability of glucose measurements permitted the patients to adjust their own insulin doses, food intake and physical activity and, thus, improve their glycaemic control. This report summarizes the available data on this tool and details how best to use this state-of-the-art modality in diabetic patients in clinical practice.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17988918     DOI: 10.1016/j.diabet.2007.05.003

Source DB:  PubMed          Journal:  Diabetes Metab        ISSN: 1262-3636            Impact factor:   6.041


  5 in total

1.  A review of the management of implanted medical devices for diabetes: trends and directions.

Authors:  Carl Edman; Darrel Drinan
Journal:  J Diabetes Sci Technol       Date:  2008-11

2.  Continuous Glucose Monitoring (CGM) Adherence in Youth With Type 1 Diabetes: Associations With Biomedical and Psychosocial Variables.

Authors:  Elisa Giani; Rebecca Snelgrove; Lisa K Volkening; Lori M Laffel
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

3.  Enzyme-mediated redox initiation for hydrogel generation and cellular encapsulation.

Authors:  Leah M Johnson; Benjamin D Fairbanks; Kristi S Anseth; Christopher N Bowman
Journal:  Biomacromolecules       Date:  2009-11-09       Impact factor: 6.988

4.  Acute Low-Volume High-Intensity Interval Exercise and Continuous Moderate-Intensity Exercise Elicit a Similar Improvement in 24-h Glycemic Control in Overweight and Obese Adults.

Authors:  Lewan Parker; Christopher S Shaw; Lauren Banting; Itamar Levinger; Karen M Hill; Andrew J McAinch; Nigel K Stepto
Journal:  Front Physiol       Date:  2017-01-09       Impact factor: 4.566

Review 5.  Continuous Glucose Monitoring Systems: A Review.

Authors:  Sandeep Kumar Vashist
Journal:  Diagnostics (Basel)       Date:  2013-10-29
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.