Literature DB >> 17986883

Analysis of efficacy and failure in proximal humerus fractures treated with locking plates.

Juan Agudelo1, Matthias Schürmann, Philip Stahel, Peter Helwig, Steven J Morgan, Wolfgang Zechel, Christian Bahrs, Anand Parekh, Bruce Ziran, Allison Williams, Wade Smith.   

Abstract

OBJECTIVE: The purpose of this study was to determine the efficacy of proximal humerus locking plates (PHLP) and to clarify predictors of loss of fixation.
DESIGN: Retrospective review of patients with proximal humerus fractures fixed with a PHLP.
SETTING: Five Level 1 trauma centers. PATIENTS: One hundred fifty-three patients (111 female, 42 male) 18 years or older with a displaced fracture or fracture-dislocation of the proximal humerus treated with a PHLP between January 1, 2001 and July 31, 2005. INTERVENTION: Demographic data, trauma mechanism, surgical approach, and perioperative complications were collected from the medical records. Fracture classification according to the AO/OTA, radiographic head-shaft angle, and screw tip-articular surface distance in true anteroposterior (AP) and axillary lateral radiographs of the shoulder were measured postoperatively. Varus malreduction was defined as a head-shaft angle of <120 degrees. MAIN OUTCOME MEASUREMENTS: Statistical analysis was done to establish correlations between loss of fixation and postoperative head-shaft angle in the true AP radiograph, patient age, fracture type, trauma mechanism, number of locking head screws, and type of plate.
RESULTS: The mean age was 62.3 +/- 15.4 years (22-92) and the mean injury severity score (ISS) was 9.5 +/- 10.16 (4-57; n = 73). The surgical approach was deltopectoral (90.2%) or transdeltoid (9.8%). No intraoperative complications were reported. The mean postoperative head-shaft angle was 130 degrees (95 degrees to 160 degrees; SD = 13). The overall incidence of loss of fixation was 13.7%. There was a statistically significant association between varus reduction (<120 degrees) and loss of fixation (30.4% when the head-shaft angle was <120 degrees versus 11% when the head-shaft angle was > or =120 degrees; P = 0.02).
CONCLUSION: This series presents the experience using PHLP in 5 Level 1 trauma centers. There were no intraoperative complications related to the locking plate systems. Despite the use of fixed-angle devices, loss of fixation occurred, primarily in the presence of varus malreduction. Our findings suggest that avoiding varus should substantially decrease the risk of postoperative failures.

Entities:  

Mesh:

Year:  2007        PMID: 17986883     DOI: 10.1097/BOT.0b013e31815bb09d

Source DB:  PubMed          Journal:  J Orthop Trauma        ISSN: 0890-5339            Impact factor:   2.512


  83 in total

1.  Surgical treatment of Neer Group VI proximal humeral fractures: retrospective comparison of PHILOS® and hemiarthroplasty.

Authors:  Christian Spross; Andreas Platz; Matthias Erschbamer; Thomas Lattmann; Michael Dietrich
Journal:  Clin Orthop Relat Res       Date:  2011-12-13       Impact factor: 4.176

2.  Comparison of two different locking plates for two-, three- and four-part proximal humeral fractures--results of an international multicentre study.

Authors:  Gerhard Konrad; Anja Hirschmüller; Laurent Audige; Simon Lambert; Ralf Hertel; Norbert P Südkamp
Journal:  Int Orthop       Date:  2011-11-30       Impact factor: 3.075

3.  [Technique and value of arthroscopic implant removal in the shoulder].

Authors:  H Lill; C Katthagen; C Voigt
Journal:  Orthopade       Date:  2011-01       Impact factor: 1.087

4.  [Challenging the dogma on inferiority of stainless steel implants for fracture fixation. An end of the controversy?].

Authors:  S Weckbach; J T Losacco; J Hahnhaussen; F Gebhard; P F Stahel
Journal:  Unfallchirurg       Date:  2012-01       Impact factor: 1.000

5.  Surgeon volume is associated with cost and variation in surgical treatment of proximal humeral fractures.

Authors:  Nitin B Jain; Ifedayo Kuye; Laurence D Higgins; Jon J P Warner
Journal:  Clin Orthop Relat Res       Date:  2012-07-24       Impact factor: 4.176

6.  The effect of inferomedial screw on postoperative shoulder function and mechanical alignment in proximal humerus fractures.

Authors:  Murat Erdoğan; Engin Eren Desteli; Yunus İmren; Ali Üztürk; Mesut Kılıç; Hicabi Sezgin
Journal:  Eur J Orthop Surg Traumatol       Date:  2013-12-12

7.  Dendritic cells tolerized with adenosine A₂AR agonist attenuate acute kidney injury.

Authors:  Li Li; Liping Huang; Hong Ye; Steven P Song; Amandeep Bajwa; Sang Ju Lee; Emily K Moser; Katarzyna Jaworska; Gilbert R Kinsey; Yuan J Day; Joel Linden; Peter I Lobo; Diane L Rosin; Mark D Okusa
Journal:  J Clin Invest       Date:  2012-10-24       Impact factor: 14.808

8.  Postoperative Evaluation of Reduction Loss in Proximal Humeral Fractures: A Comparison of Plain Radiographs and Computed Tomography.

Authors:  Xiao-Yang Jia; Yan-Xi Chen; Min-Fei Qiang; Kun Zhang; Hao-Bo Li; Yu-Chen Jiang; Yi-Jie Zhang
Journal:  Orthop Surg       Date:  2017-05-30       Impact factor: 2.071

9.  Additive fiber-cerclages in proximal humeral fractures stabilized by locking plates: no effect on fracture stabilization and rotator cuff function in human shoulder specimens.

Authors:  Christine Voigt; Christof Hurschler; Louise Rechi; Rolf Vosshenrich; Helmut Lill
Journal:  Acta Orthop       Date:  2009-08       Impact factor: 3.717

10.  [Value of MRI in preoperative diagnostics of proximal humeral fractures compared to CT and conventional radiography].

Authors:  C Voigt; M Ewig; R Vosshenrich; H Lill
Journal:  Unfallchirurg       Date:  2010-05       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.