Experimental measurement of radiological penumbra associated with intermediate energy x-rays (1 MV) and small radiosurgery field sizes.

Brian M Keller1, David J Beachey, Jean-Philippe Pignol.   

Abstract

Stereotactic radiosurgery is used to treat intracranial lesions with a high degree of accuracy. At the present time, x-ray energies at or above Co-60 gamma rays are used. Previous Monte Carlo simulations have demonstrated that intermediate energy x-ray photons or IEPs (defined to be photons in the energy range of 0.2-1.2 MeV), combined with small field sizes, produce a reduced radiological penumbra leading to a sharper dose gradient, improved dose homogeneity and sparing of critical anatomy adjacent to the target volume. This hypothesis is based on the fact that, for small x-ray fields, a dose outside the treatment volume is dictated mainly by the range of electrons set into motion by x-ray photons. The purpose of this work is: (1) to produce intermediate energy x rays using a detuned medical linear accelerator, (2) to characterize the energy of this beam, (3) to measure the radiological penumbra for IEPs and small fields to compare with that produced by 6 MV x rays or Co-60, and (4) to compare these experimental measurements with Monte Carlo computer simulations. The maximum photon energy of our IEP x-ray spectrum was measured to be 1.2 MeV. Gafchromic EBT films (ISP Technologies, Wayne, NJ) were irradiated and read using a novel digital microscopy imaging system with high spatial resolution. Under identical irradiation conditions the measured radiological penumbra widths (80%-20% distance), for field sizes ranging from 0.3 x 0.3 to 4.0 x 4.0 cm2, varied from 0.3-0.77 mm (1.2 MV) and from 1.1-2.1 mm (6 MV). Even more dramatic were the differences found when comparing the 90%-10% or the 95%-5% widths, which are in fact more significant in radiotherapy. Monte Carlo simulations agreed well with the experimental findings. The reduction in radiological penumbra could be substantial for specific clinical situations such as in the treatment of an ocular melanoma abutting the macula or for the treatment of functional disorders such as trigeminal neuralgia (a nonlethal neurological pathology) where no long-term side effect should be induced by the treatment.

Entities:  

Mesh:

Year:  2007        PMID: 17985645     DOI: 10.1118/1.2775666

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Doses to internal organs for various breast radiation techniques--implications on the risk of secondary cancers and cardiomyopathy.

Authors:  Jean-Philippe Pignol; Brian M Keller; Ananth Ravi
Journal:  Radiat Oncol       Date:  2011-01-14       Impact factor: 3.481

2.  Intermediate Megavoltage Photon Beams for Improved Lung Cancer Treatments.

Authors:  Ying Zhang; Yuanming Feng; Munir Ahmad; Xin Ming; Li Zhou; Jun Deng
Journal:  PLoS One       Date:  2015-12-16       Impact factor: 3.752

3.  Energy Modulated Photon Radiotherapy: A Monte Carlo Feasibility Study.

Authors:  Ying Zhang; Yuanming Feng; Xin Ming; Jun Deng
Journal:  Biomed Res Int       Date:  2016-02-09       Impact factor: 3.246

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.