Literature DB >> 17985640

A simple geometric algorithm to predict optimal starting gantry angles using equiangular-spaced beams for intensity modulated radiation therapy of prostate cancer.

Peter S Potrebko1, Boyd M C McCurdy, James B Butler, Adel S El-Gubtan, Zoann Nugent.   

Abstract

A fast, geometric beam angle optimization (BAO) algorithm for clinical intensity-modulated radiation therapy (IMRT) was implemented on ten localized prostate cancer patients on the Radiation Therapy Oncology Group (RTOG) 0126 protocol. The BAO algorithm computed the beam intersection volume (BIV) within the rectum and bladder using five and seven equiangular-spaced beams as a function of starting gantry angle for comparison to the V 75 Gy and V 70 Gy. A mathematical theory was presented to explain the correlation of BIV with dose and dose-volume metrics. The class solution 'W' pattern in the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle using five equiangular-spaced beams (with two separate minima centered near 20 degrees and 50 degrees) was reproduced by the 5 BIV within the rectum. A strong correlation was found between the rectal 5 BIV and the rectal V 75 Gy and V 70 Gy as a function of starting gantry angle. The BAO algorithm predicted the location of the two dosimetric minima in rectal V 75 Gy and V 70 Gy (optimal starting gantry angles) to within 5 degrees. It was demonstrated that the BIV geometric variations for seven equiangular-spaced beams were too small to translate into a strong dosimetric effect in the rectal V 75 Gy and V 70 Gy. The relatively flat distribution with starting gantry angle of the bladder V 75 Gy and V 70 Gy was reproduced by the bladder five and seven BIV for each patient. A geometric BAO method based on BIV has the advantage over dosimetric BAO methods of simplicity and rapid computation time. This algorithm can be used as a standalone optimization method or act as a rapid calculation filter to reduce the search space for a dosimetric BAO method. Given the clinically infeasible computation times of many dosimetric beam orientation optimization algorithms, this robust geometric BIV algorithm has the potential to facilitate beam angle selection for prostate IMRT in clinical practice.

Entities:  

Mesh:

Year:  2007        PMID: 17985640     DOI: 10.1118/1.2775685

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Intensity modulated radiation therapy with field rotation--a time-varying fractionation study.

Authors:  Delal Dink; Mark P Langer; Ronald L Rardin; Joseph F Pekny; Gintaras V Reklaitis; Behlul Saka
Journal:  Health Care Manag Sci       Date:  2012-01-10

2.  A data-driven approach to optimal beam/arc angle selection for liver stereotactic body radiation therapy treatment planning.

Authors:  Yang Sheng; Taoran Li; Yaorong Ge; Hui Lin; Wentao Wang; Lulin Yuan; Q Jackie Wu
Journal:  Quant Imaging Med Surg       Date:  2021-12

3.  A surrogate-based metaheuristic global search method for beam angle selection in radiation treatment planning.

Authors:  H H Zhang; S Gao; W Chen; L Shi; W D D'Souza; R R Meyer
Journal:  Phys Med Biol       Date:  2013-03-21       Impact factor: 3.609

4.  The Scatter Search Based Algorithm for Beam Angle Optimization in Intensity-Modulated Radiation Therapy.

Authors:  Ali Ghanbarzadeh; Majid Pouladian; Ali Shabestani Monfared; Seied Rabi Mahdavi
Journal:  Comput Math Methods Med       Date:  2018-06-03       Impact factor: 2.238

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.