Literature DB >> 17984622

Contrast-enhanced 64-slice computed tomography in detection and evaluation of anomalous coronary arteries.

Mustafa Karaca1, Ata Kirilmaz, Güray Oncel, Dilek Oncel, Hasan Yilmaz, Batuhan Tamci, Bülent Gurcay.   

Abstract

Anomalous coronary artery (ACA) has either an unusual origin or different anatomical course and is associated with sudden cardiac death. The absence or nonspecific symptoms of ACA make its diagnosis difficult. Mostly, ACA is diagnosed coincidentally during invasive coronary angiogram (ICA). A conventional computed tomography (CT) cannot provide detailed images of coronary arteries of the moving heart, but 64-slice CT, with its short acquisition time, can provide detailed anatomy of coronary arteries non-invasively. In this study, we assessed the validity of contrast-enhanced 64-slice CT in the evaluation of ACA. ICA was performed in 7,574 patients for the diagnosis or evaluation of occlusive coronary artery disease and detected coronary anomalies in 56 patients (0.7%). We then performed 64-slice CT in 53 patients out of the 56 patients with demonstrated or suspected coronary anomaly, showing the origin and the course of the ACA along with stenosis, except for one patient who could not be evaluated due to image distortion artifacts. Contrast-enhanced 64-slice CT was also performed in 374 patients with vague signs and symptoms, detecting coronary anomalies in 7 patients (1.2%). Thus, in the total of 59 patients undergone 64-slice CT, we were able to visualize the entire abnormal coronary tree with a high diagnostic image quality. This is the first study to demonstrate the utility of 64-slice CT in a large series of ACA. Contrast-enhanced 64-slice CT is superior to ICA to identify the presence and course of ACA and should be the first line diagnostic tool in the evaluation of ACA.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17984622     DOI: 10.1620/tjem.213.249

Source DB:  PubMed          Journal:  Tohoku J Exp Med        ISSN: 0040-8727            Impact factor:   1.848


  5 in total

1.  Dual source multidetector CT-angiography before Transcatheter Aortic Valve Implantation (TAVI) using a high-pitch spiral acquisition mode.

Authors:  W Wuest; K Anders; A Schuhbaeck; M S May; S Gauss; M Marwan; M Arnold; S Ensminger; G Muschiol; W G Daniel; M Uder; S Achenbach
Journal:  Eur Radiol       Date:  2011-08-17       Impact factor: 5.315

2.  Quantitative assessment on coronary computed tomography angiography (CCTA) image quality: comparisons between genders and different tube voltage settings.

Authors:  Teo Chee Chian; Norziana Mat Nassir; Mohd Izuan Ibrahim; Ahmad Khairuddin Md Yusof; Akmal Sabarudin
Journal:  Quant Imaging Med Surg       Date:  2017-02

3.  Anomalous origin and retropulmonary course of an atherosclerotic stenosed left circumflex coronary artery.

Authors:  J A T C Parker; A A Peivandi; S Bitschnau; N Kayhan; C F Vahl
Journal:  Int J Vasc Med       Date:  2010-06-13

4.  Application of 270 mgI/mL Iodinated Contrast Media in Dual-Source Computed Tomography Coronary Artery Imaging.

Authors:  Jun Zhang; Bo He; Yuan-Ling Wang; Dan Han
Journal:  Acta Cardiol Sin       Date:  2014-11       Impact factor: 2.672

5.  Prospectively gated axial CT coronary angiography: preliminary experiences with a novel low-dose technique.

Authors:  Oliver Klass; Martin Jeltsch; Sebastian Feuerlein; Horst Brunner; Hans-Dieter Nagel; Matthew J Walker; Hans-Juergen Brambs; Martin H K Hoffmann
Journal:  Eur Radiol       Date:  2008-11-15       Impact factor: 5.315

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.