Quantification of dosimetric impact of implementation of on-board imaging (OBI) for IMRT treatment of head-and-neck malignancies.

Joshua D Lawson1, Eric Elder, Tim Fox, Lawrence Davis, Ian Crocker.   

Abstract

Implementation of daily kilovoltage imaging for setup verification improves the reproducibility of treatment by eliminating small random setup errors. We evaluate the dosimetric consequences of such shifts, not yet evaluated, in a group of head-and-neck cancer patients (ENT) treated with intensity modulated radiation therapy (IMRT) at Emory University. Twelve patients with ENT malignancies were analyzed. On-Board Imaging (OBI) was used in at least 70% of each patient's treatment sessions. An isodose distribution was generated for each fraction, with the isocenter shifted to its calculated location prior to OBI repositioning. These plans were summed and then compared to the simulation plan for coverage of target structures. For these 12 patients, there were a total of 18 planning target volumes (PTV). The mean (range) percent reduction in minimum dose was 12.1% (-1.0 to 43.3). For 10 right necks and 9 left necks treated, the mean percent reduction in minimum dose was 11.8% (-0.6 to 39.7) and 13.3% (-3.6 to 31.2), respectively. The mean reduction in mean dose to the PTV was 1.3% (0 to 5.1). The mean reduction in mean dose to the right and left necks was 1.0% (0.2 to 3.9) and 1.13% (0.4 to 3.4), respectively. From this analysis, we conclude that the shifts made were small and random, with essentially no change in mean dose delivered to target structures. There is, however, significant improvement in the minimum dose delivered. Underdosing even a small portion of the tumor potentially sacrifices the probability of local control; correcting these setup errors seems desirable.

Entities:  

Mesh:

Year:  2007        PMID: 17980830     DOI: 10.1016/j.meddos.2007.02.008

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  4 in total

1.  Effect of daily setup errors on individual dose distribution in conventional radiotherapy: an initial study.

Authors:  Akihiro Takemura; Saori Shoji; Sinichi Ueda; Yuichi Kurata; Tomoyasu Kumano; Shigeyuki Takamatsu; Masayuki Suzuki
Journal:  Radiol Phys Technol       Date:  2009-05-01

2.  Two-dimensional imaging of tumour control probabilities and normal tissue complication probabilities.

Authors:  Marta Szlag; Krzysztof Slosarek
Journal:  Rep Pract Oncol Radiother       Date:  2010-04-09

3.  Evaluating positional accuracy using megavoltage cone-beam computed tomography for IMRT with head-and-neck cancer.

Authors:  Kana Motegi; Ryosuke Kohno; Takashi Ueda; Toshiyuki Shibuya; Takaki Ariji; Mitsuhiko Kawashima; Tetsuo Akimoto
Journal:  J Radiat Res       Date:  2014-01-20       Impact factor: 2.724

4.  Dosimetric assessment of rigid setup error by CBCT for HN-IMRT.

Authors:  Danielle Worthy; Qiuwen Wu
Journal:  J Appl Clin Med Phys       Date:  2010-05-28       Impact factor: 2.102