Thermal disinfection of hotels, hospitals, and athletic venues hot water distribution systems contaminated by Legionella species.

Varvara Mouchtouri1, Emmanuel Velonakis, Christos Hadjichristodoulou.   

Abstract

Legionella spp. (> or = 500 cfu liter(-1)) were detected in 92 of 497 water distribution systems (WDS) examined. Thermal disinfection was applied at 33 WDS. After the first and second application of the disinfection procedure, 15 (45.4%) and 3 (9%) positive for remedial actions WDS were found, respectively. Legionella pneumophila was more resistant to thermal disinfection than Legionella non-pneumophila spp. (relative risk [RR]=5.4, 95% confidence intervals [CI]=1-35). WDS of hotels with oil heater were more easily disinfected than those with electrical or solar heater (RR=0.4 95% CI=0.2-0.8). Thermal disinfection seems not to be efficient enough to eliminate legionellae, unless repeatedly applied and in combination with extended heat flushing, and faucets chlorine disinfection.

Entities:  

Mesh:

Year:  2007        PMID: 17980243     DOI: 10.1016/j.ajic.2007.01.002

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  17 in total

1.  Epidemiological Investigation of Legionella pneumophila Serogroup 2 to 14 Isolates from Water Samples by Amplified Fragment Length Polymorphism and Sequence-Based Typing and Detection of Virulence Traits.

Authors:  Anna Katsiaflaka; Spyros Pournaras; Ioulia Kristo; Varvara A Mouchtouri; Maria Kyritsi; Emmanuel Velonakis; Alkiviadis C Vatopoulos; Christos Hadjichristodoulou
Journal:  Appl Environ Microbiol       Date:  2016-09-30       Impact factor: 4.792

2.  Legionellosis and Recent Advances in Technologies for Legionella Control in Premise Plumbing Systems: A Review.

Authors:  Kelsie M Carlson; Laura A Boczek; Soryong Chae; Hodon Ryu
Journal:  Water (Basel)       Date:  2020-03-02       Impact factor: 3.103

3.  Insertion sequences as highly resolutive genomic markers for sequence type 1 Legionella pneumophila Paris.

Authors:  Mike Vergnes; Christophe Ginevra; Elisabeth Kay; Philippe Normand; Jean Thioulouse; Sophie Jarraud; Max Maurin; Dominique Schneider
Journal:  J Clin Microbiol       Date:  2010-10-27       Impact factor: 5.948

4.  Physical and chemical parameter correlations with technical and technological characteristics of heating systems and the presence of Legionella spp. in the hot water supply.

Authors:  Anita Rakić; Nives Štambuk-Giljanović
Journal:  Environ Monit Assess       Date:  2016-01-05       Impact factor: 2.513

5.  Viability and infectivity of viable but nonculturable Legionella pneumophila strains induced at high temperatures.

Authors:  Sílvia Cervero-Aragó; Barbara Schrammel; Elisabeth Dietersdorfer; Regina Sommer; Christian Lück; Julia Walochnik; Alexander Kirschner
Journal:  Water Res       Date:  2019-04-09       Impact factor: 11.236

6.  Convective Mixing in Distal Pipes Exacerbates Legionella pneumophila Growth in Hot Water Plumbing.

Authors:  William J Rhoads; Amy Pruden; Marc A Edwards
Journal:  Pathogens       Date:  2016-03-12

Review 7.  Determination of viable legionellae in engineered water systems: Do we find what we are looking for?

Authors:  Alexander K T Kirschner
Journal:  Water Res       Date:  2016-02-12       Impact factor: 11.236

8.  Legionella species colonization of water distribution systems, pools and air conditioning systems in cruise ships and ferries.

Authors:  Georgia Goutziana; Varvara A Mouchtouri; Maria Karanika; Antonios Kavagias; Nikolaos E Stathakis; Kostantinos Gourgoulianis; Jenny Kremastinou; Christos Hadjichristodoulou
Journal:  BMC Public Health       Date:  2008-11-24       Impact factor: 3.295

9.  Effect of Common Drinking Water Disinfectants, Chlorine and Heat, on Free Legionella and Amoebae-Associated Legionella.

Authors:  Sílvia Cervero-Aragó; Sarah Rodríguez-Martínez; Antoni Puertas-Bennasar; Rosa M Araujo
Journal:  PLoS One       Date:  2015-08-04       Impact factor: 3.240

10.  Necessity and effect of combating Legionella pneumophila in municipal shower systems.

Authors:  Ragnhild Wiik; Anne Vatland Krøvel
Journal:  PLoS One       Date:  2014-12-09       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.