Literature DB >> 17979436

Multiplexed operation of a micromachined ultrasonic droplet ejector array.

Thomas P Forbes1, F Levent Degertekin, Andrei G Fedorov.   

Abstract

A dual-sample ultrasonic droplet ejector array is developed for use as a soft-ionization ion source for multiplexed mass spectrometry (MS). Such a multiplexed ion source aims to reduce MS analysis time for multiple analyte streams, as well as allow for the synchronized ejection of the sample(s) and an internal standard for quantitative results and mass calibration. Multiplexing is achieved at the device level by division of the fluid reservoir and separating the active electrodes of the piezoelectric transducer for isolated application of ultrasonic wave energy to each domain. The transducer is mechanically shaped to further reduce the acoustical crosstalk between the domains. Device design is performed using finite-element analysis simulations and supported by experimental characterization. Isolated ejection of approximately 5 microm diameter water droplets from individual domains in the micromachined droplet ejector array at around 1 MHz frequency is demonstrated by experiments. The proof-of-concept demonstration using a dual-sample device also shows potential for multiplexing with larger numbers of analytes.

Entities:  

Mesh:

Year:  2007        PMID: 17979436     DOI: 10.1063/1.2785156

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  4 in total

1.  Electrohydrodynamics of charge separation in droplet-based ion sources with time-varying electrical and mechanical actuation.

Authors:  Thomas P Forbes; F Levent Degertekin; Andrei G Fedorov
Journal:  J Am Soc Mass Spectrom       Date:  2010-01-18       Impact factor: 3.109

2.  Electrochemical Ionization and Analyte Charging in the Array of Micromachined UltraSonic Electrospray (AMUSE) Ion Source.

Authors:  Thomas P Forbes; F Levent Degertekin; Andrei G Fedorov
Journal:  J Electroanal Chem (Lausanne)       Date:  2010-07-01       Impact factor: 4.464

3.  Comparison of the internal energy deposition of Venturi-assisted electrospray ionization and a Venturi-assisted array of micromachined ultrasonic electrosprays (AMUSE).

Authors:  Christina Y Hampton; Catherine J Silvestri; Thomas P Forbes; Mark J Varady; J Mark Meacham; Andrei G Fedorov; F Levent Degertekin; Facundo M Fernández
Journal:  J Am Soc Mass Spectrom       Date:  2008-06-28       Impact factor: 3.109

4.  Characterization of charge separation in the Array of Micromachined UltraSonic Electrospray (AMUSE) ion source for mass spectrometry.

Authors:  Thomas P Forbes; R Brent Dixon; David C Muddiman; F Levent Degertekin; Andrei G Fedorov
Journal:  J Am Soc Mass Spectrom       Date:  2009-05-20       Impact factor: 3.109

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.