Literature DB >> 17979297

Ultrasensitive PCR and real-time detection from human genomic samples using a bidirectional flow microreactor.

Lin Chen1, Jonathan West, Pierre-Alain Auroux, Andreas Manz, Philip J R Day.   

Abstract

In this paper we present a reliable bidirectional flow DNA amplification microreactor for processing real-world genomic samples. This system shares the low-power thermal responsiveness of a continuous flow reactor with the low surface area to volume ratio character of stationary reactors for reducing surface inhibitory effects. Silanization with dimethyldichlorosilane in combination with dynamic surface passivation was used to enhance PCR compatibility and enable efficient amplification. For real-time fragment amplification monitoring we have implemented an epimodal fluorescent detection capability. The passivated bidirectional flow system was ultrasensitive, achieving an RNase P gene detection limit of 24 human genome copies with a reaction efficiency of 77%. This starts to rival the performance of a conventional real-time PCR instrument with a reaction efficiency of 93% and revitalizes flow-through PCR as a viable component of lab on a chip DNA analysis formats.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17979297     DOI: 10.1021/ac701668k

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Quantitative polymerase chain reaction using infrared heating on a microfluidic chip.

Authors:  Yingjie Yu; Bowei Li; Christopher A Baker; Xinyu Zhang; Michael G Roper
Journal:  Anal Chem       Date:  2012-03-02       Impact factor: 6.986

2.  Multiplexed real-time polymerase chain reaction on a digital microfluidic platform.

Authors:  Zhishan Hua; Jeremy L Rouse; Allen E Eckhardt; Vijay Srinivasan; Vamsee K Pamula; Wiley A Schell; Jonathan L Benton; Thomas G Mitchell; Michael G Pollack
Journal:  Anal Chem       Date:  2010-03-15       Impact factor: 6.986

3.  Real-time toxicity prediction of Aconitum stewing system using extractive electrospray ionization mass spectrometry.

Authors:  Zi-Dong Qiu; Jin-Long Chen; Wen Zeng; Ying Ma; Tong Chen; Jin-Fu Tang; Chang-Jiang-Sheng Lai; Lu-Qi Huang
Journal:  Acta Pharm Sin B       Date:  2019-09-11       Impact factor: 11.413

Review 4.  Simplifying the complex: accessible microfluidic solutions for contemporary processes within in vitro diagnostics.

Authors:  Nathan K Khosla; Jake M Lesinski; Monika Colombo; Léonard Bezinge; Andrew J deMello; Daniel A Richards
Journal:  Lab Chip       Date:  2022-09-13       Impact factor: 7.517

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.