| Literature DB >> 1797846 |
C P Verwey-van Wissen1, P M Koopman-Kimenai, T B Vree.
Abstract
A high-performance liquid chromatographic method has been developed for the detection, separation and measurement of codeine and its metabolites norcodeine, morphine and normorphine, with their glucuronide conjugates. The glucuronidase Escherichia coli type VIIA hydrolyses codeine-6-glucuronide completely and is used for the construction of the calibration curves of codeine-6-glucuronide. Enzymic hydrolysis of codeine-6-glucuronide depends on the specific activity of the glucuronidase applied. Examples are shown of a volunteer who is able to form morphine from codeine and one who is unable to do so.Entities:
Mesh:
Substances:
Year: 1991 PMID: 1797846 DOI: 10.1016/0378-4347(91)80534-j
Source DB: PubMed Journal: J Chromatogr