Literature DB >> 17975814

Influence of pulse repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface.

Mariane Gonçalves1, Silmara Aparecida Milori Corona, Regina Guenka Palma-Dibb, Jesus Djalma Pécora.   

Abstract

The study evaluated the in vitro influence of pulse-repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superficial, 1.0 and 1.5 mm) of the same dental area, using the same sample. Surface treatments were acid conditioning solely (control) and Er:YAG laser irradiation (80 mJ) followed by acid conditioning, with different pulse-repetition rates (1, 2, 3, or 4 Hz). Single bond/Z-250 system was used. The samples were stored in distilled water at 37 degrees C for 24 h, and then the first test (superficial dentine) was performed. The bond failures were analyzed. Following, the specimens were identified, grounded until 1.0- and 1.5-mm depths, submitted again to the treatments and to the second and, after that, to third-bond tests on a similar procedure and failure analysis. ANOVA and Tukey test demonstrated a significant difference (p < 0.001) for treatment and treatment x depth interaction (p < 0.05). The tested depths did not show influence (p > 0.05) on the bond strength of dentin-resin interface. It may be concluded that Er:YAG laser with 1, 2, 3, or 4 Hz combined with acid conditioning did not increase the resin tensile bond strength to dentin, regardless of dentin depth.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 17975814     DOI: 10.1002/jbm.a.31636

Source DB:  PubMed          Journal:  J Biomed Mater Res A        ISSN: 1549-3296            Impact factor:   4.396


  4 in total

1.  Effect of low fluency dentin conditioning on tensile bond strength of composite bonded to Er:YAG laser-prepared dentin: a preliminary study.

Authors:  B Bahrami; N Askari; M Tielemans; D Heysselaer; L Lamard; A Peremans; C Nyssen-Behets; S Nammour
Journal:  Lasers Med Sci       Date:  2010-03-23       Impact factor: 3.161

2.  Effect of erbium:yttrium-aluminum-garnet laser energies on superficial and deep dentin microhardness.

Authors:  Michelle Alexandra Chinelatti; Walter Raucci-Neto; Silmara Aparecida Milori Corona; Regina Guenka Palma-Dibb
Journal:  Lasers Med Sci       Date:  2008-11-04       Impact factor: 3.161

3.  Microtensile bond strength of an etch-and-rinse adhesive to enamel and dentin after Er:YAG laser pretreatment with different pulse durations.

Authors:  Esra Firat; Sevil Gurgan; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2010-08-31       Impact factor: 3.161

4.  Bonding of adhesives to Er:YAG laser-treated dentin.

Authors:  Eugenia Koliniotou-Koumpia; Pantelis Kouros; Lazaros Zafiriadis; Effimia Koumpia; Pavlos Dionysopoulos; Vassilis Karagiannis
Journal:  Eur J Dent       Date:  2012-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.