Frontomaxillary and mandibulomaxillary facial angles at 11 + 0 to 13 + 6 weeks in fetuses with trisomy 18.

M Borenstein1, N Persico, I Strobl, J Sonek, K H Nicolaides.   

Abstract

OBJECTIVE: To define the relative position of the maxilla and mandible in fetuses with trisomy 18 at 11 + 0 to 13 + 6 weeks of gestation.
METHODS: A three-dimensional (3D) volume of the fetal head was obtained before karyotyping at 11 + 0 to 13 + 6 weeks of gestation in 36 fetuses subsequently found to have trisomy 18, and 200 chromosomally normal fetuses. The frontomaxillary facial (FMF) angle and the mandibulomaxillary facial (MMF) angle were measured in a mid-sagittal view of the fetal face.
RESULTS: In the chromosomally normal group both the FMF and MMF angles decreased significantly with crown-rump length (CRL). In the trisomy 18 fetuses the FMF angle was significantly greater and the angle was above the 95(th) centile of the normal range in 21 (58.3%) cases. In contrast, in trisomy 18 fetuses the MMF angle was significantly smaller than that in normal fetuses and the angle was below the 5(th) centile of the normal range in 12 (33.3%) cases.
CONCLUSIONS: Trisomy 18 at 11 + 0 to 13 + 6 weeks of gestation is associated with both mid-facial hypoplasia and micrognathia or retrognathia that can be documented by measurement of the FMF angle and MMF angle, respectively.

Entities:  

Mesh:

Year:  2007        PMID: 17975785     DOI: 10.1002/uog.5188

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  5 in total

1.  Fetal MRI as a complement to US in the evaluation of cleft lip and palate.

Authors:  L Manganaro; A Tomei; F Fierro; M Di Maurizio; P Sollazzo; M E Sergi; V Vinci; S Bernardo; D Irimia; P Cascone; M Marini
Journal:  Radiol Med       Date:  2011-04-19       Impact factor: 3.469

2.  Study on normal reference value of fetal facial profile markers during the first trimester of pregnancy.

Authors:  Xueqin Ji; Zhen Han; Yang Wu; Simin Zhang
Journal:  Transl Pediatr       Date:  2022-01

3.  Frontomaxillary facial angle measurement in screening for trisomy 18 at 11 + 0 to 13 + 6 weeks of pregnancy: a double-centre study.

Authors:  Bartosz Czuba; Wojciech Cnota; Agata Wloch; Piotr Wegrzyn; Krzysztof Sodowski; Miroslaw Wielgos; Dariusz Borowski
Journal:  Biomed Res Int       Date:  2013-10-01       Impact factor: 3.411

Review 4.  First Trimester Ultrasound in Prenatal Diagnosis-Part of the Turning Pyramid of Prenatal Care.

Authors:  Ran Neiger
Journal:  J Clin Med       Date:  2014-09-05       Impact factor: 4.241

5.  Application of an individualized nomogram in first-trimester screening for trisomy 21.

Authors:  Y Sun; L Zhang; D Dong; X Li; J Wang; C Yin; L C Poon; J Tian; Q Wu
Journal:  Ultrasound Obstet Gynecol       Date:  2021-07       Impact factor: 7.299

  5 in total