Literature DB >> 17975281

Construction of a modified capacitive overlap MR coil for imaging of small animals and objects in a clinical whole-body scanner.

T Seierstad1, K Røe, B Høvik.   

Abstract

During the last two decades, there has been an explosive increase in the number of MR investigations involving genetically manipulated mice and rats. Many of the animal studies are performed in a more or less clinical environment, where whole-body MR scanners are the only option available. The quality and acquisition time of MR images have improved with the development of novel RF coil technologies. This communication describes the construction of a small inductively coupled capacitive overlap transmit-receive MR coil for imaging of small animals and objects in a clinical MR scanner. The MR coil presented here is a modified version of the bridged loop-gap coil and consists of two tube-shaped coupled resonance circuits, where the primary circuit partly encapsulates the imaging (secondary) circuit. By rotating the concentric primary coil relative to the secondary coil tuning over a range of several hundred kilohertz is obtained. The coil performance was characterized experimentally by acquiring high-resolution anatomical, diffusion and perfusion MR images as well as the acquisition of proton spectra of a mouse tumour.

Entities:  

Mesh:

Year:  2007        PMID: 17975281     DOI: 10.1088/0031-9155/52/22/N02

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Longitudinal magnetic resonance imaging-based assessment of vascular changes and radiation response in androgen-sensitive prostate carcinoma xenografts under androgen-exposed and androgen-deprived conditions.

Authors:  Kathrine Røe; Therese Seierstad; Alexandr Kristian; Lars Tore Gyland Mikalsen; Gunhild Mari Mælandsmo; Albert J van der Kogel; Anne Hansen Ree; Dag Rune Olsen
Journal:  Neoplasia       Date:  2010-10       Impact factor: 5.715

2.  A 20-channel receive-only mouse array coil for a 3 T clinical MRI system.

Authors:  Boris Keil; Graham C Wiggins; Christina Triantafyllou; Lawrence L Wald; Florian M Meise; Laura M Schreiber; Klaus J Klose; Johannes T Heverhagen
Journal:  Magn Reson Med       Date:  2011-03-23       Impact factor: 4.668

3.  Liposomal doxorubicin improves radiotherapy response in hypoxic prostate cancer xenografts.

Authors:  Eirik Hagtvet; Kathrine Røe; Dag R Olsen
Journal:  Radiat Oncol       Date:  2011-10-07       Impact factor: 3.481

4.  Early prediction of response to radiotherapy and androgen-deprivation therapy in prostate cancer by repeated functional MRI: a preclinical study.

Authors:  Kathrine Røe; Manish Kakar; Therese Seierstad; Anne H Ree; Dag R Olsen
Journal:  Radiat Oncol       Date:  2011-06-08       Impact factor: 3.481

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.