Literature DB >> 17974893

Biologic augmentation of rotator cuff tendon-healing with use of a mixture of osteoinductive growth factors.

Scott A Rodeo1, Hollis G Potter, Sumito Kawamura, A Simon Turner, Hyon Jeong Kim, Brent L Atkinson.   

Abstract

BACKGROUND: Clinical studies have demonstrated a high rate of incomplete healing of rotator cuff tendon repair. Since healing of such a repair is dependent on bone ingrowth into the repaired tendon, we hypothesized that osteoinductive growth factors would improve rotator cuff tendon-healing.
METHODS: Seventy-two skeletally mature sheep underwent detachment of the infraspinatus tendon followed by immediate repair. The animals received one of three treatments at the tendon-bone interface: (1) an osteoinductive bone protein extract on a Type-I collagen sponge carrier, (2) the collagen sponge carrier alone, and (3) no implant. The animals were killed at six and twelve weeks, and the repaired rotator cuff was evaluated with use of magnetic resonance imaging, plain radiographs, histologic analysis, and biomechanical testing.
RESULTS: A gap consistently formed between the end of the repaired tendon and bone in this model, with reparative scar tissue and new bone spanning the gap. Magnetic resonance imaging showed that the volume of newly formed bone (p < 0.05) and soft tissue (p < 0.05) in the tendon-bone gap were greater in the growth factor-treated animals compared with the collagen sponge control group at both time-points. Histologic analysis showed a fibrovascular tissue in the interface between tendon and bone, with a more robust fibrocartilage zone between the bone and the tendon in the growth factor-treated animals. The repairs that were treated with the osteoinductive growth factors had significantly greater failure loads at six weeks and twelve weeks (p < 0.05); however, when the data were normalized by tissue volume, there were no differences between the groups, suggesting that the treatment with growth factor results in the formation of poor-quality scar tissue rather than true tissue regeneration. The repairs that were treated with the collagen sponge carrier alone had significantly greater stiffness than the growth factor-treated group at twelve weeks (p = 0.005).
CONCLUSIONS: This model tests the effects of growth factors on scar tissue formation in a gap between tendon and bone. The administration of osteoinductive growth factors resulted in greater formation of new bone, fibrocartilage, and soft tissue, with a concomitant increase in tendon attachment strength but less stiffness than repairs treated with the collagen sponge carrier alone.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17974893     DOI: 10.2106/JBJS.C.01627

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  73 in total

1.  Effect of implanting a soft tissue autograft in a central-third patellar tendon defect: biomechanical and histological comparisons.

Authors:  Kirsten R C Kinneberg; Marc T Galloway; David L Butler; Jason T Shearn
Journal:  J Biomech Eng       Date:  2011-09       Impact factor: 2.097

2.  The effects of low-intensity pulsed ultrasound on tendon-bone healing in a transosseous-equivalent sheep rotator cuff model.

Authors:  Vedran Lovric; Michael Ledger; Jerome Goldberg; Wade Harper; Nicky Bertollo; Matthew H Pelletier; Rema A Oliver; Yan Yu; William R Walsh
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-31       Impact factor: 4.342

Review 3.  Strategies in biologic augmentation of rotator cuff repair: a review.

Authors:  Emilie V Cheung; Luz Silverio; John W Sperling
Journal:  Clin Orthop Relat Res       Date:  2010-06       Impact factor: 4.176

Review 4.  [Rotator cuff repair: single- vs double-row. Clinical and biomechanical results].

Authors:  M H Baums; T Kostuj; H-M Klinger; R Papalia
Journal:  Orthopade       Date:  2016-02       Impact factor: 1.087

Review 5.  Biological augmentation of rotator cuff tendon repair.

Authors:  David Kovacevic; Scott A Rodeo
Journal:  Clin Orthop Relat Res       Date:  2008-02-10       Impact factor: 4.176

6.  Posterior Soft Tissue Repair After Primary THA is Durable at Mid-term Followup: A Prospective MRI Study.

Authors:  Alexander S McLawhorn; Hollis G Potter; Michael B Cross; Friedrich Boettner; Weiyang Lim; Yuo-yu Lee; Paul M Pellicci
Journal:  Clin Orthop Relat Res       Date:  2015-06-06       Impact factor: 4.176

7.  Rotator cuff repair augmentation in a rat model that combines a multilayer xenograft tendon scaffold with bone marrow stromal cells.

Authors:  Rei Omi; Anne Gingery; Scott P Steinmann; Peter C Amadio; Kai-Nan An; Chunfeng Zhao
Journal:  J Shoulder Elbow Surg       Date:  2015-09-19       Impact factor: 3.019

Review 8.  Advances in biologic augmentation for rotator cuff repair.

Authors:  Sahishnu Patel; Anthony P Gualtieri; Helen H Lu; William N Levine
Journal:  Ann N Y Acad Sci       Date:  2016-10-17       Impact factor: 5.691

Review 9.  Mechanisms of tendon injury and repair.

Authors:  Stavros Thomopoulos; William C Parks; Daniel B Rifkin; Kathleen A Derwin
Journal:  J Orthop Res       Date:  2015-03-02       Impact factor: 3.494

Review 10.  An overview of recent patents on musculoskeletal interface tissue engineering.

Authors:  Rohit T Rao; Daniel P Browe; Christopher J Lowe; Joseph W Freeman
Journal:  Connect Tissue Res       Date:  2015-11-17       Impact factor: 3.417

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.