Literature DB >> 17973197

Influence of indoor air quality (IAQ) objectives on air-conditioned offices in Hong Kong.

Pui-Shan Hui1, Kwok-Wai Mui, Ling-Tim Wong.   

Abstract

It is costly to sample all air pollutants of a general community. Air sampling should be conducted based on a practical assessment strategy and monitoring plan. In Hong Kong, the Environmental Protection Department (HKEPD) launched an Indoor Air Quality (IAQ) certification scheme to grade workplace IAQ as 'Excellent' or 'Good' by measuring the levels of nine common indoor air pollutants, namely carbon dioxide (CO(2)), carbon monoxide (CO), respirable suspended particulates (RSP), nitrogen dioxide (NO(2)), ozone (O(3)), formaldehyde (HCHO), total volatile organic compounds (TVOC), radon (Rn), and airborne bacteria count (ABC). Although average office IAQ performance has been improved since the implementation of this certification scheme, there are still resource issues and technical difficulties. To streamline the assessment of office IAQ performance, this study proposes a simple index of IAQ benchmarks formulated in compliance with the HKEPD requirements. In particular, three of the nine listed common air pollutants were selected as the 'representatives' for the overall satisfactory IAQ. Together with the assessment results of 422 Hong Kong air-conditioned offices, the index was evaluated in terms of test sensitivity, specificity and predictive values. Proved to be feasible to describe the IAQ of some air-conditioned offices, this IAQ index would be a useful tool for policymakers, building owners and professionals to quantify IAQ performance in offices and to make decisions on resources and manpower management for efficient mitigation actions.

Mesh:

Substances:

Year:  2007        PMID: 17973197     DOI: 10.1007/s10661-007-9994-6

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  1 in total

1.  The indoor environmental index and its relationship with symptoms of office building occupants.

Authors:  Demetrios J Moschandreas; Sait C Sofuoglu
Journal:  J Air Waste Manag Assoc       Date:  2004-11       Impact factor: 2.235

  1 in total
  5 in total

Review 1.  The Carcinogenic Effects of Formaldehyde Occupational Exposure: A Systematic Review.

Authors:  Carmela Protano; Giuseppe Buomprisco; Vittoria Cammalleri; Roberta Noemi Pocino; Daniela Marotta; Stefano Simonazzi; Francesca Cardoni; Marta Petyx; Sergio Iavicoli; Matteo Vitali
Journal:  Cancers (Basel)       Date:  2021-12-29       Impact factor: 6.639

Review 2.  Occupational scenarios and exposure assessment to formaldehyde: A systematic review.

Authors:  Vittoria Cammalleri; Roberta Noemi Pocino; Daniela Marotta; Carmela Protano; Federica Sinibaldi; Stefano Simonazzi; Marta Petyx; Sergio Iavicoli; Matteo Vitali
Journal:  Indoor Air       Date:  2021-10-27       Impact factor: 6.554

3.  Respiratory Symptoms and Skin Sick Building Syndrome among Office Workers at University Hospital, Chiang Mai, Thailand: Associations with Indoor Air Quality, AIRMED Project.

Authors:  Vithawat Surawattanasakul; Wachiranun Sirikul; Ratana Sapbamrer; Kampanat Wangsan; Jinjuta Panumasvivat; Pheerasak Assavanopakun; Supang Muangkaew
Journal:  Int J Environ Res Public Health       Date:  2022-08-31       Impact factor: 4.614

4.  Impacts of earthquake aftermath on indoor carbon monoxide levels in Turkish coffeehouses environment in duzce, Turkey.

Authors:  T Bahcebasi; C Guler; H Kandis; I H Kara
Journal:  Iran J Public Health       Date:  2012-01-31       Impact factor: 1.429

5.  The reproducibility of indoor air pollution (IAP) measurement: a test case for the measurement of key air pollutants from the pan frying of fish samples.

Authors:  Ki-Hyun Kim; Yong-Hyun Kim; Bo-Won Kim; Jeong-Hyeon Ahn; Min-Suk Bae; Richard J C Brown
Journal:  ScientificWorldJournal       Date:  2014-06-25
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.