Literature DB >> 17973195

A new paradigm for the design of audible alarms that convey urgency information.

Richard R McNeer1, Jorge Bohórquez, Ozcan Ozdamar, Albert J Varon, Paul Barach.   

Abstract

OBJECTIVE: The current international standard (IEC 60601-1-8) stipulates that medical device audible alarms should be priority-encoded and validated for efficacy. Evidence suggests that the melodic alarms described in the standard are not functioning as originally intended. We present a multi-disciplinary, human factors paradigm for audible alarm development whereby urgency information is encoded via modulation of the physical characteristics of sounds. We also test the feasibility of this approach using information measures.
METHODS: We designed series of experimental sounds that varied along controlled physical and acoustical dimensions. Subjects rated these sound series for perceived urgency. Based on these ratings, selected sounds from each series were assigned a priority category from 'low' to 'high' - we call these resulting sets of sounds 'urgency-codecs'. The method of categorical judgments (based on information theory) was used to compare each urgency-codec for ability to convey urgency information.
RESULTS: Subjects were consistent in their ratings of the three series of experimental sounds for perceived urgency. The urgency data pertaining to one of the series (harmonic interval) was successfully fit to a psychophysical empirical law. The urgency-codec derived from another sound series (melodic interval) was found to have the highest signal (correct interpretation of urgency level by subjects) transmission rate.
CONCLUSIONS: The proposed paradigm is feasible, and it offers an evidence-based strategy for alarm sound design and testing. This approach would be performed before implementation of new alarm sounds in clinical settings, and should result in development of alarm sounds that satisfy the requirements of priority-encoding and validation.

Entities:  

Mesh:

Year:  2007        PMID: 17973195     DOI: 10.1007/s10877-007-9096-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Anesthesia alarms in context: an observational study.

Authors:  F J Seagull; P M Sanderson
Journal:  Hum Factors       Date:  2001       Impact factor: 2.888

2.  The perceived urgency of auditory warning alarms used in the hospital operating room is inappropriate.

Authors:  Todd A Mondor; G Allen Finley
Journal:  Can J Anaesth       Date:  2003-03       Impact factor: 5.063

3.  The magical number seven plus or minus two: some limits on our capacity for processing information.

Authors:  G A MILLER
Journal:  Psychol Rev       Date:  1956-03       Impact factor: 8.934

4.  On the psychophysical law.

Authors:  S S STEVENS
Journal:  Psychol Rev       Date:  1957-05       Impact factor: 8.934

5.  Recognition accuracy of current operating room alarms.

Authors:  R G Loeb; B R Jones; R A Leonard; K Behrman
Journal:  Anesth Analg       Date:  1992-10       Impact factor: 5.108

6.  Measuring the performance of audible alarms for anaesthesia.

Authors:  Sarah Williams; Paul C W Beatty
Journal:  Physiol Meas       Date:  2005-08       Impact factor: 2.833

7.  Video analysis of prolonged uncorrected esophageal intubation. Level One Trauma Anesthesia Simulation Group.

Authors:  C F Mackenzie; P Martin; Y Xiao
Journal:  Anesthesiology       Date:  1996-06       Impact factor: 7.892

8.  Improved monitoring of preterm infants by Fuzzy Logic.

Authors:  M Wolf; M Keel; K von Siebenthal; H U Bucher; K Geering; Y Lehareinger; P Niederer
Journal:  Technol Health Care       Date:  1996-08       Impact factor: 1.285

9.  Are there too many alarms in the intensive care unit? An overview of the problems.

Authors:  C Meredith; J Edworthy
Journal:  J Adv Nurs       Date:  1995-01       Impact factor: 3.187

10.  Subjective rating scales: science or art?

Authors:  John Annett
Journal:  Ergonomics       Date:  2002-11-15       Impact factor: 2.778

View more
  4 in total

1.  A nurses' alarm fatigue questionnaire: development and psychometric properties.

Authors:  Camellia Torabizadeh; Amirhossein Yousefinya; Farid Zand; Mahnaz Rakhshan; Mohammad Fararooei
Journal:  J Clin Monit Comput       Date:  2016-11-15       Impact factor: 2.502

Review 2.  Real-time alerts and reminders using information systems.

Authors:  Jonathan P Wanderer; Warren S Sandberg; Jesse M Ehrenfeld
Journal:  Anesthesiol Clin       Date:  2011-07-21

Review 3.  Medical audible alarms: a review.

Authors:  Judy Edworthy
Journal:  J Am Med Inform Assoc       Date:  2012-10-25       Impact factor: 4.497

Review 4.  Technological advances in perioperative monitoring: Current concepts and clinical perspectives.

Authors:  Geetanjali Chilkoti; Rachna Wadhwa; Ashok Kumar Saxena
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2015 Jan-Mar