Literature DB >> 17968902

Real-time MR imaging of myocardial regional function using strain-encoding (SENC) with tissue through-plane motion tracking.

El-Sayed H Ibrahim1, Matthias Stuber, Ahmed S Fahmy, Khaled Z Abd-Elmoniem, Tetsuo Sasano, M Roselle Abraham, Nael F Osman.   

Abstract

PURPOSE: To implement real-time myocardial strain-encoding (SENC) imaging in combination with tracking the tissue displacement in the through-plane direction.
MATERIALS AND METHODS: SENC imaging was combined with the slice-following technique by implementing three-dimensional (3D) selective excitation. Certain adjustments were implemented to reduce scan time to one heartbeat. A total of 10 volunteers and five pigs were scanned on a 3T MRI scanner. Spatial modulation of magnetization (SPAMM)-tagged images were acquired on planes orthogonal to the SENC planes for comparison. Myocardial infarction (MI) was induced in two pigs and the resulting SENC images were compared to standard delayed-enhancement (DE) images.
RESULTS: The strain values computed from SENC imaging with slice-following showed significant difference from those acquired without slice-following, especially during systole (P < 0.01). The strain curves computed from the SENC images with and without slice-following were similar to those computed from the orthogonal SPAMM images, with and without, respectively, tracking the tag line displacement in the strain direction. The resulting SENC images showed good agreement with the DE images in identifying MI in infarcted pigs.
CONCLUSION: Correction of through-plane motion in real-time cardiac functional imaging is feasible using slice-following. The strain measurements are more accurate than conventional SENC measurements in humans and animals, as validated with conventional MRI tagging. (c) 2007 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2007        PMID: 17968902     DOI: 10.1002/jmri.21125

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  15 in total

Review 1.  Imaging sequences in cardiovascular magnetic resonance: current role, evolving applications, and technical challenges.

Authors:  El-Sayed H Ibrahim
Journal:  Int J Cardiovasc Imaging       Date:  2012-03-25       Impact factor: 2.357

2.  Meshless deformable models for 3D cardiac motion and strain analysis from tagged MRI.

Authors:  Xiaoxu Wang; Ting Chen; Shaoting Zhang; Joël Schaerer; Zhen Qian; Suejung Huh; Dimitris Metaxas; Leon Axel
Journal:  Magn Reson Imaging       Date:  2014-08-23       Impact factor: 2.546

3.  Navigated DENSE strain imaging for post-radiofrequency ablation lesion assessment in the swine left atria.

Authors:  Ehud J Schmidt; Maggie M Fung; Pelin Aksit Ciris; Ting Song; Ajit Shankaranarayanan; Godtfred Holmvang; Sandeep N Gupta; Miguel Chaput; Robert A Levine; Jeremy Ruskin; Vivek Y Reddy; Andre D'avila; Anthony H Aletras; Stephan B Danik
Journal:  Europace       Date:  2013-09-06       Impact factor: 5.214

4.  Improved real-time tagged MRI using REALTAG.

Authors:  Weiyi Chen; Nam Gyun Lee; Dani Byrd; Shrikanth Narayanan; Krishna S Nayak
Journal:  Magn Reson Med       Date:  2019-12-24       Impact factor: 4.668

Review 5.  Myocardial tagging by cardiovascular magnetic resonance: evolution of techniques--pulse sequences, analysis algorithms, and applications.

Authors:  El-Sayed H Ibrahim
Journal:  J Cardiovasc Magn Reson       Date:  2011-07-28       Impact factor: 5.364

6.  Quantitative detection of changes in regional wall motion using real time strain-encoded cardiovascular magnetic resonance.

Authors:  Keigo Kawaji; Noreen Nazir; John A Blair; Victor Mor-Avi; Stephanie Besser; Kohei Matsumoto; Jacob P Goes; Darius Dabir; Lukas Stoiber; Sebastian Kelle; Seyedeh Mahsa Zamani; Luise Holzhauser; Roberto M Lang; Amit R Patel
Journal:  Magn Reson Imaging       Date:  2019-09-01       Impact factor: 2.546

7.  Imaging three-dimensional myocardial mechanics using navigator-gated volumetric spiral cine DENSE MRI.

Authors:  Xiaodong Zhong; Bruce S Spottiswoode; Craig H Meyer; Christopher M Kramer; Frederick H Epstein
Journal:  Magn Reson Med       Date:  2010-10       Impact factor: 4.668

8.  MR elastography as a method for the assessment of myocardial stiffness: comparison with an established pressure-volume model in a left ventricular model of the heart.

Authors:  Arunark Kolipaka; Kiaran P McGee; Philip A Araoz; Kevin J Glaser; Armando Manduca; Anthony J Romano; Richard L Ehman
Journal:  Magn Reson Med       Date:  2009-07       Impact factor: 4.668

9.  Strain-encoded cardiac MRI as an adjunct for dobutamine stress testing: incremental value to conventional wall motion analysis.

Authors:  Grigorios Korosoglou; Dirk Lossnitzer; Dieter Schellberg; Antje Lewien; Angela Wochele; Tim Schaeufele; Mirja Neizel; Henning Steen; Evangelos Giannitsis; Hugo A Katus; Nael F Osman
Journal:  Circ Cardiovasc Imaging       Date:  2009-01-26       Impact factor: 7.792

10.  Comprehensive enhanced methodology of an MRI-based automated left-ventricular chamber quantification algorithm and validation in chemotherapy-related cardiotoxicity.

Authors:  Julia Kar; Michael V Cohen; Samuel A McQuiston; Christopher M Malozzi
Journal:  J Med Imaging (Bellingham)       Date:  2020-11-16
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.