Literature DB >> 17968454

Portable XRF analysis of occupational air filter samples from different workplaces using different samplers: final results, summary and conclusions.

Martin Harper1, Bruce Pacolay, Patrick Hintz, David L Bartley, James E Slaven, Michael E Andrew.   

Abstract

This paper concludes a five-year program on research into the use of a portable X-ray fluorescence (XRF) analyzer for analyzing lead in air sampling filters from different industrial environments, including mining, manufacturing and recycling. The results from four of these environments have already been reported. The results from two additional metal processes are presented here. At both of these sites, lead was a minor component of the total airborne metals and interferences from other elements were minimal. Nevertheless, only results from the three sites where lead was the most abundant metal were used in the overall calculation of method accuracy. The XRF analyzer was used to interrogate the filters, which were then subjected to acid digestion and analysis by inductively-coupled plasma optical-emission spectroscopy (ICP-OES). The filter samples were collected using different filter-holders or "samplers" where the size (diameter), depth and homogeneity of aerosol deposit varied from sampler to sampler. The aerosol collection efficiencies of the samplers were expected to differ, especially for larger particles. The distribution of particles once having entered the sampler was also expected to differ between samplers. Samplers were paired to allow the between-sampler variability to be addressed, and, in some cases, internal sampler wall deposits were evaluated and compared to the filter catch. It was found, rather surprisingly, that analysis of the filter deposits (by ICP-OES) of all the samplers gave equivalent results. It was also found that deposits on some of the sampler walls, which in some protocols are considered part of the sample, could be significant in comparison to the filter deposit. If it is concluded that wall-deposits should be analyzed, then XRF analysis of the filter can only give a minimum estimate of the concentration. Techniques for the statistical analysis of field data were also developed as part of this program and have been reported elsewhere. The results, based on data from the three workplaces where lead was the major element present in the samples, are summarized here. A limit of detection and a limit of quantitation are provided. Analysis of some samples using a second analyzer with a different X-ray source technology indicated reasonable agreement for some metals (but this was not evaluated for lead). Provided it is only necessary to analyze the filters, most personal samplers will provide acceptable results when used with portable XRF analysis for lead around applicable limit values.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17968454     DOI: 10.1039/b710591f

Source DB:  PubMed          Journal:  J Environ Monit        ISSN: 1464-0325


  4 in total

1.  Assessment of occupational exposure to manganese and other metals in welding fumes by portable X-ray fluorescence spectrometer.

Authors:  Wisanti Laohaudomchok; Jennifer M Cavallari; Shona C Fang; Xihong Lin; Robert F Herrick; David C Christiani; Marc G Weisskopf
Journal:  J Occup Environ Hyg       Date:  2010-08       Impact factor: 2.155

2.  Rapid Analysis of the Size Distribution of Metal-Containing Aerosol.

Authors:  Jae Hong Park; Imali A Mudunkotuwa; Kathryn J Crawford; T Renée Anthony; Vicki H Grassian; Thomas M Peters
Journal:  Aerosol Sci Technol       Date:  2016-10-20       Impact factor: 2.908

3.  Immediate screening of lead exposure in the workplace using portable X-ray fluorescence.

Authors:  Jean-Philippe Gorce; Martin Roff
Journal:  J Occup Environ Hyg       Date:  2016       Impact factor: 2.155

Review 4.  Recent Advances in Occupational Exposure Assessment of Aerosols.

Authors:  Martin Harper
Journal:  Int J Environ Res Public Health       Date:  2020-09-18       Impact factor: 3.390