Literature DB >> 17965999

High-precision measurements of cementless acetabular components using model-based RSA: an experimental study.

Thomas Baad-Hansen1, Søren Kold, Bart L Kaptein, Kjeld Søballe.   

Abstract

BACKGROUND: In RSA, tantalum markers attached to metal-backed acetabular cups are often difficult to detect on stereo radiographs due to the high density of the metal shell. This results in occlusion of the prosthesis markers and may lead to inconclusive migration results. Within the last few years, new software systems have been developed to solve this problem. We compared the precision of 3 RSA systems in migration analysis of the acetabular component.
MATERIAL AND METHODS: A hemispherical and a non-hemispherical acetabular component were mounted in a phantom. Both acetabular components underwent migration analyses with 3 different RSA systems: conventional RSA using tantalum markers, an RSA system using a hemispherical cup algorithm, and a novel model-based RSA system.
RESULTS: We found narrow confidence intervals, indicating high precision of the conventional marker system and model-based RSA with regard to migration and rotation. The confidence intervals of conventional RSA and model-based RSA were narrower than those of the hemispherical cup algorithm-based system regarding cup migration and rotation.
INTERPRETATION: The model-based RSA software combines the precision of the conventional RSA software with the convenience of the hemispherical cup algorithm-based system. Based on our findings, we believe that these new tools offer an improvement in the measurement of acetabular component migration.

Entities:  

Mesh:

Year:  2007        PMID: 17965999     DOI: 10.1080/17453670710014095

Source DB:  PubMed          Journal:  Acta Orthop        ISSN: 1745-3674            Impact factor:   3.717


  10 in total

1.  The effects of different weight-bearing regimes on press-fit cup stability: a randomised study with five years of follow-up using radiostereometry.

Authors:  Olof Wolf; Per Mattsson; Jan Milbrink; Sune Larsson; Hans Mallmin
Journal:  Int Orthop       Date:  2011-12-07       Impact factor: 3.075

2.  Excessive distal migration of fiber-mesh coated femoral stems.

Authors:  Thomas Baad-Hansen; Søren Kold; Niels Olsen; Finn Christensen; Kjeld Søballe
Journal:  Acta Orthop       Date:  2011-04-19       Impact factor: 3.717

3.  Comparison of trabecular metal cups and titanium fiber-mesh cups in primary hip arthroplasty: a randomized RSA and bone mineral densitometry study of 50 hips.

Authors:  Thomas Baad-Hansen; Søren Kold; Poul Torben Nielsen; Mogens Berg Laursen; Poul Hedevang Christensen; Kjeld Soballe
Journal:  Acta Orthop       Date:  2011-03-25       Impact factor: 3.717

4.  Measurement of migration of a humeral head resurfacing prosthesis using radiostereometry without implant marking: an experimental study.

Authors:  Olof Sköldenberg; Magnus Odquist
Journal:  Acta Orthop       Date:  2011-03-24       Impact factor: 3.717

5.  No association between serum metal ions and implant fixation in large-head metal-on-metal total hip arthroplasty.

Authors:  Mette Holm Hjorth; Kjeld Søballe; Stig Storgaard Jakobsen; Nina Dyrberg Lorenzen; Inger Mechlenburg; Maiken Stilling
Journal:  Acta Orthop       Date:  2014-05-21       Impact factor: 3.717

6.  Accuracy and Precision of Three-Dimensional Low Dose CT Compared to Standard RSA in Acetabular Cups: An Experimental Study.

Authors:  Cyrus Brodén; Henrik Olivecrona; Gerald Q Maguire; Marilyn E Noz; Michael P Zeleznik; Olof Sköldenberg
Journal:  Biomed Res Int       Date:  2016-07-10       Impact factor: 3.411

7.  The Use of Porous Titanium Coating and the Largest Possible Head Do Not Affect Early Cup Fixation: A 2-Year Report from a Randomized Controlled Trial.

Authors:  Georgios Tsikandylakis; Kristian R L Mortensen; Kirill Gromov; Anders Troelsen; Henrik Malchau; Maziar Mohaddes
Journal:  JB JS Open Access       Date:  2020-12-15

8.  Combined and hybrid marker models for radiostereometry assessment of polyethylene liner motion in dual mobility hip prosthesis: a proof-of-concept study.

Authors:  Peter Bo Jørgensen; Bart L Kaptein; Kjeld Søballe; Stig S Jakobsen; Maiken Stilling
Journal:  Eur Radiol Exp       Date:  2021-12-15

9.  Dependence of model-based RSA accuracy on higher and lower implant surface model quality.

Authors:  Frank Seehaus; Judith Emmerich; Bart L Kaptein; Henning Windhagen; Christof Hurschler
Journal:  Biomed Eng Online       Date:  2013-04-16       Impact factor: 2.819

10.  Superior accuracy of model-based radiostereometric analysis for measurement of polyethylene wear: A phantom study.

Authors:  M Stilling; S Kold; S de Raedt; N T Andersen; O Rahbek; K Søballe
Journal:  Bone Joint Res       Date:  2012-08-01       Impact factor: 5.853

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.