Literature DB >> 17965483

Restenosis and stent fracture following sirolimus-eluting stent (SES) implantation.

Masanori Okumura1, Yukio Ozaki, Junichi Ishii, Shino Kan, Hiroyuki Naruse, Shigeru Matsui, Makoto Ishikawa, Kousuke Hattori, Tomoko Gochi, Tadashi Nakano, Akira Yamada, Shigeru Kato, Sadako Motoyama, Masayoshi Sarai, Yasushi Takagi, Tevfik F Ismail, Masanori Nomura, Hitoshi Hishida.   

Abstract

BACKGROUND: Restenosis still occurs, even with the sirolimus-eluting stent (SES), and the precise mechanisms and the impact of stent fracture on restensosis have not yet been elucidated. METHODS AND
RESULTS: Intravascular ultrasound (IVUS)-guided SES implantation was performed in 184 lesions in 151 patients with stable and unstable angina. Serial (pre-, post- and follow-up) quantitative coronary angiography analysis was obtained in 169 lesions in 138 patients (angiographic follow-up rate: 91%) and 12-month clinical follow-up was done in all patients. Restenosis occurred in 13 (7.7%) of 169 lesions. Stent fracture occurred in 4 (2.4%) of 169 lesions at follow-up. Of the 13 restenotic lesions, 8 had intimal hyperplasia, 4 had stent fracture, and 1 had late stent thrombosis at 7 months. Although multivariate logistic regression analysis revealed that minimal lumen area (min-LA) post (p=0.027), total stent length (p=0.003) and diabetes (p=0.032) were significant independent predictors of restenosis, univariate analysis showed that stent fracture was more common in the restenosis than in the non-restenosis groups (p=0.001).
CONCLUSIONS: Although min-LA post by IVUS, total stent length by QCA and diabetes are independent predictors for angiographic restenosis, stent fracture occurred in 4 lesions (2.4%) and all of them resulted in restenosis (31% of the restenosis). The impact of stent fracture and its potential role in the development of restenosis deserves further study.

Entities:  

Mesh:

Year:  2007        PMID: 17965483     DOI: 10.1253/circj.71.1669

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  12 in total

1.  Long-term angiographic outcomes of post-sirolimus-eluting stent restenosis in Japanese patients.

Authors:  Nobuyuki Miyai; Noriyuki Kinoshita; Keisuke Oota; Takeshi Yamada; Reo Nakamura; Hidekazu Irie; Tetsuo Hashimoto; Shyunichi Tamaki; Hiroaki Matsubara
Journal:  Heart Vessels       Date:  2010-10-27       Impact factor: 2.037

2.  Prevalence and prognosis of coronary stent gap detected by multi-detector CT: a follow-up study.

Authors:  Xinghua Zhang; Li Yang; Haiyue Ju; Fan Zhang; Jian Wu; Bin He; Yundai Chen
Journal:  Eur Radiol       Date:  2012-04-27       Impact factor: 5.315

3.  Utility of myocardial fractional flow reserve for prediction of restenosis following sirolimus-eluting stent implantation.

Authors:  Hideshi Ishii; Toru Kataoka; Yoshiki Kobayashi; Takara Tsumori; Hiroaki Takeshita; Ryo Matsumoto; Nobuyuki Shirai; Hiroki Nishioka; Takao Hasegawa; Shinji Nakata; Yoshihisa Shimada; Shoichi Ehara; Takashi Muro; Minoru Yoshiyama
Journal:  Heart Vessels       Date:  2011-01-08       Impact factor: 2.037

4.  Impact of the bifurcation angle on major cardiac events after cross-over single stent strategy in unprotected left main bifurcation lesions: 3-dimensional quantitative coronary angiographic analysis.

Authors:  Kisaki Amemiya; Takenori Domei; Masashi Iwabuchi; Shinichi Shirai; Kenji Ando; Masahiko Goya; Hiroyoshi Yokoi; Masakiyo Nobuyoshi
Journal:  Am J Cardiovasc Dis       Date:  2014-12-29

5.  Extensive late-acquired incomplete stent apposition after sirolimus-eluting stent implantation.

Authors:  Hyun-Chul Choi; Seung-Ho Hur; Chang-Wook Nam; Yun-Kyeong Cho; Hyungseop Kim; Nam-Hee Park; Yoon-Nyun Kim; Kwon-Bae Kim
Journal:  Korean Circ J       Date:  2010-01-27       Impact factor: 3.243

6.  Intravascular ultrasound-guided drug-eluting stent implantation is associated with improved clinical outcomes in patients with unstable angina and complex coronary artery true bifurcation lesions.

Authors:  Liang Chen; Tian Xu; Xian-Jun Xue; Jun-Jie Zhang; Fei Ye; Nai-Liang Tian; Shao-Liang Chen
Journal:  Int J Cardiovasc Imaging       Date:  2018-07-06       Impact factor: 2.357

7.  Complete fracture of sirolimus-eluting stent in a saphenous vein graft to left anterior descending artery.

Authors:  Sun Hong Yoo; Seung Won Jin; Sung Ho Her; Hee Jeoung Yoon; Hyoung Doo Kim; Yun Sun Im; Ki Bae Seung; Jae Hyung Kim
Journal:  Korean Circ J       Date:  2009-06-30       Impact factor: 3.243

Review 8.  Intravascular foreign bodies: danger of unretrieved fragmented medical devices.

Authors:  Minori Tateishi; Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

9.  A case of a zotarolimus-eluting stent fracture in the left anterior descending artery in a patient undergoing hemodialysis.

Authors:  In Hye Cha; Seong Hwan Kim; Sang Yup Lim; Jeong Chun Ahn; Woo Hyuk Song
Journal:  Chonnam Med J       Date:  2011-04-26

10.  Detection of very delayed coronary stent fracture using a novel fluoroscopic stent visualization technique against intravascular ultrasound: A case series.

Authors:  Feifei Yang; Liwei Zhang; Dangsheng Huang; Dong Shen; Yongjiang Ma; Minjun Xiong; Chunhong Zhang; Miao Tian
Journal:  Medicine (Baltimore)       Date:  2017-05       Impact factor: 1.889

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.