Literature DB >> 17964962

Enhanced diagnosis of coronary artery disease in women by dobutamine thallium-201 ST-segment/heart rate slope and thallium-201 myocardial SPECT.

Dong-Feng Yeih1, Por-Jau Huang, Yi-Lwun Ho.   

Abstract

BACKGROUND/
PURPOSE: The diagnosis of coronary artery disease (CAD) in women presents a great challenge because of poor exercise capacity and inadequate heart rate response during stress test. The clinical significance of stress-related ST-segment/heart rate slope (ST/HR slope) value for evaluating CAD in women remains controversial. Therefore, we conducted the present study to assess the diagnostic performance of dobutamine ST/HR slope in women, compared with myocardial perfusion study using thallium-201 single-photon emission computed tomography (Tl-201 SPECT).
METHODS: A total of 51 female patients with suspected CAD underwent simultaneous 12-lead electrocardiographic recording during 3-minute stages of dobutamine infusion as well as Tl-201 SPECT, and coronary angiography was performed within 2 weeks post Tl-201 SPECT. The sensitivity, specificity, positive predictive value and negative predictive value of dobutamine ST/HR slope and Tl-201 SPECT were assessed, and the results of coronary angiography were used as a gold standard.
RESULTS: The sensitivity, specificity and accuracy of dobutamine ST/HR slope in detecting CAD were 43%, 83% and 61%, and those of Tl-201 SPECT were 71%, 87% and 78%, respectively. However, using both positive results of Tl-201 SPECT and ST/HR slope for detecting CAD, the diagnostic specificity increased from 87% to 96%. Using both negative results of Tl-201 SPECT and ST/HR slope to exclude CAD, the negative predictive value increased from 71% to 85%. The accuracy of dobutamine ST/HR slope in detecting CAD was not affected by the use of beta-blockers.
CONCLUSION: Dobutamine ST/HR slope is less sensitive and less accurate than Tl-201 SPECT for detecting CAD in women. However, it adds diagnostic benefit to Tl-201 SPECT with only a little extra calculation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17964962     DOI: 10.1016/S0929-6646(08)60048-0

Source DB:  PubMed          Journal:  J Formos Med Assoc        ISSN: 0929-6646            Impact factor:   3.282


  4 in total

1.  Gender differences in the diagnostic accuracy of SPECT myocardial perfusion imaging: a bivariate meta-analysis.

Authors:  Aline Iskandar; Brendan Limone; Matthew W Parker; Andrew Perugini; Hyejin Kim; Charles Jones; Brian Calamari; Craig I Coleman; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2012-11-13       Impact factor: 5.952

2.  Single photon emission computed tomography for the diagnosis of coronary artery disease: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2010-06-01

3.  Diagnostic performance of myocardial perfusion imaging with conventional and CZT single-photon emission computed tomography in detecting coronary artery disease: A meta-analysis.

Authors:  Valeria Cantoni; Roberta Green; Wanda Acampa; Emilia Zampella; Roberta Assante; Carmela Nappi; Valeria Gaudieri; Teresa Mannarino; Renato Cuocolo; Eugenio Di Vaia; Mario Petretta; Alberto Cuocolo
Journal:  J Nucl Cardiol       Date:  2019-05-14       Impact factor: 5.952

Review 4.  Diagnostic performance of stress myocardial perfusion imaging for coronary artery disease: a systematic review and meta-analysis.

Authors:  Marcus C de Jong; Tessa S S Genders; Robert-Jan van Geuns; Adriaan Moelker; M G Myriam Hunink
Journal:  Eur Radiol       Date:  2012-04-19       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.