Kouwa Yamashita1, Madoka Takahashi, Satoshi Tsukamoto, Mitsuteru Numazawa, Mitsunobu Okuyama, Seijiro Honma.
Abstract
Simultaneous quantification method of six corticosteroids, cortisone, cortisol, cortexolone, corticosterone, dehydrocorticosterone and deoxycorticosterone, by LC-electrospray ionization (ESI)-MS in a positive mode using novel picolinoyl derivatization was investigated. Conversion of each corticosteroid into the corresponding picolinoyl derivative was performed by mixed anhydride method using picolinic acids and 2-methyl-6-nitrobenzoic anhydride. Derivatization proceeded smoothly to afford the corresponding 21-monopicolinoyl derivatives. Positive ion-ESI mass spectra of the picolinoyl derivatives were dominated by the appearance of [M+H](+) as base peaks. The picolinoyl derivatives provided 5-10 times higher ESI response in the LC-ESI-MS-selected reaction monitoring (SRM) when compared to those of underivatized molecules in a positive LC-ESI-MS mode. The use of the picolinoyl ester, solid-phase extraction, and deuterium labeled internal standards enabled to determine the concentrations of these corticosteroids in human saliva simultaneously by LC-ESI-MS-SRM.Entities:
Mesh:
Substances:
Year: 2007 PMID: 17964584 DOI: 10.1016/j.chroma.2007.10.023