An MRI-compatible foot-loading device for assessment of internal tissue deformation.

Marc Petre1, Ahmet Erdemir, Peter R Cavanagh.   

Abstract

It is well known that mechanical forces acting within the soft tissues of the foot can contribute to the formation of neuropathic ulcers in people with diabetes. Presently, only surface measurements of plantar pressure are used clinically to estimate risk status due to mechanical loading. It is currently not known how surface measurements relate to the three-dimensional (3-D) internal stress/strain state of the foot. This article describes the development of a foot-loading device that allows for the direct observation of the internal deformation of foot tissues under known forces. Ground reaction forces and plantar pressure distributions during normal walking were measured in ten healthy young adults. One instant in the gait cycle, when pressure under the metatarsal heads reached a peak, was extracted for simulation in an MR imager. T1-weighted 3-D gradient echo MRI sets were collected as the simulated walking ground reaction force was incrementally applied to the foot by the novel foot-loading device. The sub-metatarsal head soft-tissue thickness decreased rapidly at first and then reached a plateau. Peak plantar pressure measurements collected within the loading device (161+/-75kPa) were lower in magnitude and less focal than pressures measured during walking (492+/-91kPa). This finding implies that although the device successfully applied full peak walking ground reaction forces to the foot, they were not distributed in the same manner as during walking. Although not representative of gait, the data collected from this in vivo mechanical test are suitable for determination of foot tissue material properties or, when combined with finite element modeling, to examine the relationship between surface loading and internal stress.

Entities:  

Mesh:

Year:  2007        PMID: 17959184     DOI: 10.1016/j.jbiomech.2007.09.018

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  Optimization of nonlinear hyperelastic coefficients for foot tissues using a magnetic resonance imaging deformation experiment.

Authors:  Marc Petre; Ahmet Erdemir; Vassilis P Panoskaltsis; Thomas A Spirka; Peter R Cavanagh
Journal:  J Biomech Eng       Date:  2013-06       Impact factor: 2.097

2.  An elaborate data set characterizing the mechanical response of the foot.

Authors:  Ahmet Erdemir; Pavana A Sirimamilla; Jason P Halloran; Antonie J van den Bogert
Journal:  J Biomech Eng       Date:  2009-09       Impact factor: 2.097

Review 3.  Technologies to monitor the health of loaded skin tissues.

Authors:  Dan L Bader; Peter R Worsley
Journal:  Biomed Eng Online       Date:  2018-04-12       Impact factor: 2.819

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.